Environmental Qualification Form
Apollo SL70R Installation Manual
41
A
PPENDIX
A. E
NVIRONMENTAL
Q
UALIFICATION
F
ORM
The Apollo SL70R has been tested to the following environmental categories per proce-
dures defined in RTCA/DO-160D.
Environmental Qualification Form
Nomenclature: Apollo SL70R
Part No.: 430-6067-xx
TSO No.: TSO_C74c
Manufacturer:
UPS Aviation Technologies
2345 Turner Road SE
Salem, Oregon 97302
Conditions
Section Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Category B1 with:
In-flight Loss of Cooling
4.5.4
No cooling required
Altitude
4.6.1
Equipment tested to 25,000 feet
Decompression
4.6.2
Equipment tested for decompression to 25,000 feet
Overpressure
4.6.3
Equipment tested for overpressure
Temperature Variation
5.0
Equipment tested to Category C, 2
°
C/min
Humidity
6.0
Equipment tested to Category A, standard humidity environ-
ment
Operational Shocks and Crash
Safety
7
Equipment tested for both operational and crash safety shocks.
(Equipment operates normally after crash safety and operational
shock.)
Vibration
8.0
Equipment tested without shock mounts to Categories S(B,M)
Explosion Proofness
9.0
Equipment identified as Category X, no test required
Waterproofness
10.0
Equipment identified as Category X, no test required
Fluids Susceptibility
11.0
Equipment identified as Category X, no test required
Sand and Dust
12.0
Equipment identified as Category X, no test required
Fungus Resistance
13.0
Equipment identified as Category X, no test required
Salt Spray
14.0
Equipment identified as Category X, no test required
Magnetic Effect
15.0
Equipment is Class Z
Power Input
16.0
Equipment tested to Categories A (28 volt systems) & B (14
and 28 volt systems)
Voltage Spike
17.0
Equipment tested to Category A
Audio Frequency Conducted Sus-
ceptibility – Power Inputs
18.0
Equipment tested to Categories A & B
Induced Signal Susceptibility
19.0
Equipment tested to Category Z
Radio Frequency Susceptibility
(Radiated and Conducted)
20
Equipment tested to Category V
Emission of Radio Frequency En-
ergy
21
Equipment tested to Category M*
Lightning Induced Transient Sus-
ceptibility
22.0
Equipment tested to A3 and B2
Lightning Direct Effects
23.0
Equipment identified as Category X, no test required
Icing
24.0
Equipment identified as Category X, no test required
Remarks: *TSO requirements do not require emission testing above 1.2GHz. Intentional radiators at the second
harmonic, 2.18GHz and at the fourth harmonic, 4.36GHz, may be above the limits as specified by DO-160D. The
SL70R meets all of the environmental qualification requirements of TSO-C74c, it was qualified to and met the
higher DO-160D standard with the exception as indicated above.
Содержание Apollo SL70R
Страница 1: ...Apollo Mode A C Transponder Model SL70R Installation Manual April 2003 560 0408 01 ...
Страница 4: ...Apollo SL70R Installation Manual iv NOTES ...
Страница 8: ...Table of Contents Apollo SL70R Installation Manual iv NOTES ...
Страница 14: ...General Information Apollo SL70R Installation Manual 6 NOTES ...
Страница 23: ...Installation Procedures Apollo SL70R Installation Manual 15 NOTES ...
Страница 24: ...Installation Procedures Apollo SL70R Installation Manual 16 NOTES ...
Страница 27: ...Post Installation and Configuration Procedures Apollo SL70R Installation Manual 19 NOTES ...
Страница 28: ...Post Installation and Configuration Procedures Apollo SL70R Installation Manual 20 NOTES ...
Страница 31: ...Troubleshooting Apollo SL70R Installation Manual 23 NOTES ...
Страница 32: ...Troubleshooting Apollo SL70R Installation Manual 24 NOTES ...
Страница 34: ...Limitations Apollo SL70R Installation Manual 26 NOTES ...
Страница 36: ...Periodic Maintenance Apollo SL70R Installation Manual 28 NOTES ...
Страница 48: ...Serial Interface Specification Apollo SL70R Installation Manual 40 NOTES ...
Страница 50: ...Environmental Qualification Form Apollo SL70R Installation Manual 42 NOTES ...
Страница 51: ......