Section 3 - Troubleshooting
Machine Operation Check List
104045-021 - AB62 Work Platform - European Model
Page 3-7
U
PPER
C
ONTROL
B
OX
P
OWER
-U
P
• Both Emergency Stops are pulled out (upper and lower).
• Lower Control Box key switch in PLATFORM position. Platform key switch on.
• LEDs on DMR-30 illuminated:
• BT1-01 (platform selected)
• LEDs on DMT-30 illuminated:
• BT1-11 & BT1-12 (limit switch)
• BT1-05 (tilt)
E
NGINE
S
TART
• Operate start switch.
• LED’s on DMR-30 illuminated:
• BT3-03 (start input).
• LEDs on DMT-30 illuminated:
• BT5-11 (starter output)
• BT5-08 (glow plug output-diesel only)
• BT4-04 (oil pressure)
B
OOM
L
IFT
F
UNCTION
R
ISER
U
P
• Function enabled - foot switch depressed.
• LEDs on DMR-30 Illuminated:
• BT5-12 (riser up output)
• BT5-06 (throttle output)
• BT6-10 (high flow valve output).
• LEDs on DMT-30 illuminated:
• BT4-03 (foot switch), BT 3-09 (riser up).
R
ISER
D
OWN
• Function enabled - foot switch depressed.
• LED’s on DMR-30 illuminated:
• BT6-01 (riser down output)
• BT5-06 (throttle output)
• BT6-10 (high flow valve output)
• LED’s on DMT-30 illuminated
• BT4-03 (foot switch)
• BT 4-08 (riser down)
B
OOM
U
P
• Function enabled - foot switch depressed.
• LED’s on DMR-30 illuminated:
• BT5-09 (boom up output)
• BT5-06 (throttle output)
• BT6-12 (low flow valve output)
• LEDs on DMT-30 illuminated:
• BT4-03 (foot pedal)
• BT4-09 (boom up)