Section 3 - Troubleshooting
Machine Operation Check List
104045-021 - AB62 Work Platform - European Model
Page 3-9
J
IB
J
IB
U
P
• Function enabled - foot switch depressed.
• LEDs on DMR-30 Illuminated:
• BT7-06 (jib up output)
• BT5-06 (throttle output)
• BT6-12 (low flow valve output).
• LEDs on DMT-30 illuminated:
• BT4-03 (foot pedal)
• BT4-07 (jib up)
J
IB
D
OWN
• Function enabled - foot switch depressed.
• LEDs on DMR-30 Illuminated:
• BT7-07 (jib down output)
• BT5-06 (throttle output)
• BT6-12 (low flow valve output)
• LEDs on DMT-30 illuminated:
• BT4-03 (foot pedal)
• BT4-02 (jib down)
C
AGE
R
OTATE
C
AGE
R
IGHT
• Function enabled - foot switch depressed.
• LEDs on DMR-30 Illuminated:
• BT7-03 (cage rotate right output)
• BT5-06 (throttle output)
• BT6-12 (low flow valve output).
• LEDs on DMT-30 illuminated:
• BT4-03 (foot pedal)
• BT4-01 (cage rotate right)
C
AGE
L
EFT
• Function enabled - foot pedal depressed.
• LEDs on DMR-30 Illuminated:
• BT7-04 (cage rotate left output)
• BT5-06 (throttle output)
• BT6-12 (low flow valve output).
• LEDs on DMT-30 illuminated:
• BT4-03 (foot pedal)
• BT4-12 (cage rotate left)
C
AGE
T
RIM
U
P
• Function enabled - foot switch depressed.
• LEDs on DMR-30 Illuminated:
• BT6-05 (cage trim up output)
• BT5-06 (throttle output)
• BT6-12 (low flow valve output)
• LEDs on DMT-30 illuminated:
• BT4-03 (foot pedal)
• BT4-11 (cage trim up)