Machine Operation Check List
Section 3 - Troubleshooting
Page 3-6
104045-021 - AB62 Work Platform - European Model
• BT7-07 (jib down output to valve)
• BT6-12 (low flow valve output)
• BT5-06 (throttle output).
C
AGE
R
OTATE
C
AGE
R
IGHT
• Function enabled.
• LEDs on DMR-30 illuminated:
• BT4-03 (cage right input)
• BT7-03 (cage right output to valve)
• BT6-12 (low flow valve output)
• BT5-06 (throttle output).
C
AGE
L
EFT
• Function enabled.
• LEDs on DMR-30 illuminated:
• BT4-02 (cage left input)
• BT7-04 (cage left output to valve)
• BT6-12 (low flow valve output)
• BT5-06 (throttle output).
C
AGE
T
RIM
U
P
• Function enabled.
• LEDs on DMR-30 illuminated:
• BT2-12 (cage trim up input)
• BT6-05 (cage trim up output to valve)
• BT6-12 (low flow valve output)
• BT5-07 (throttle output).
C
AGE
T
RIM
D
OWN
• Function enabled.
• LEDs on DMR-30 illuminated:
• BT4-01 (cage trim down input)
• BT6-06 (cage trim down output to valve)
• BT6-12 (low flow valve output)
• BT5-07 (throttle output).
A
UXILIARY
P
OWER
(E
MERGENCY
F
UNCTIONS
)
• Both Emergency Stops are pulled out (upper and lower).
• Auxiliary Switch enabled.
• Relay #9 activated (12 volts at relay #9, terminals #30 & #87).
NOTE: