Machine Operation Check List
Section 3 - Troubleshooting
Page 3-4
104045-021 - AB62 Work Platform - European Model
3-7 M
ACHINE
O
PERATION
C
HECK
L
IST
L
OWER
C
ONTROL
B
OX
E
LECTRICAL
P
OWER
U
P
• Both Emergency Stop Switches are pulled out.
• Lower control box key switch is in CHASSIS position.
• Upper controls key is ON.
• BT1-03 chassis selected is illuminated.
• Other LEDs on DMR-30 that may be illuminated:
• BT1-05 (tilt)
• BT2-01 (telescope interlock)
• BT1-11 (lift interlock #1)
• BT1-12 (lift interlock #2).
• The CPU LED on the DMR-30 should be flashing ON/OFF.
• The BUSS LED on the DMR-30 should be flashing ON/OFF.
• The INPUT LED should be flashing ON/OFF.
E
NGINE
S
TART
• BT1-02 on DMR-30 (start) is illuminated when operating start switch.
• The hour meter should flash.
• BT4-08 (oil pressure input) will illuminate while engine is running.
NOTE:
If no oil pressure is detected, ignition signal is deactivated. The engine will not continue to run.
G
LOW
P
LUG
• BT1-08 on DMR-30 is illuminated.
• Glow plugs are automatic.
B
OOM
Speed control knob in UPPER control box must be turned past 5 to operate.
B
OOM
U
P
• Function enable is pushed.
• LEDs on DMR-30 are illuminated:
• BT1-03 (chassis selected)
• BT2-04 (lift input)
• BT5-09 (lift output to valve)
• BT6-12 (low flow output)
• BT5-06 (throttle output).
B
OOM
D
OWN
• Function enable pushed.
• LEDs on DMR-30 illuminated:
• BT1-03 (chassis selected)
• BT2-05 (boom down input)
• BT6-04 (boom down output to valve)
• BT6-12 (low flow output)
• BT5-06 (mid throttle output).
B
OOM
R
ISER
U
P
• Function enable pushed.
• LEDs on DMR-30 illuminated:
• BT1-03 (chassis selected)
• BT2-02 (riser up input)
• BT5-12 (riser up to valve output)
• BT6-10 (high flow output to valve)