Tapping capacity
DI0000104
40
35
30
25
20
15
10
5
0
2
4
6
8
10
12
14
16
18
20
22
60 °C
65 °C
70 °C
75 °C
80 °C
85 °C
A
B
Item
Description
A
Return temperature °C
B
Tapping capacity in litres/minute (l/min)
Cold water warming 50 K (10-60 °C)
DI0000105
1200
200
300
400
500
600
700
800
900
1000
1100
100
0
2
4
6
8
10
12
14
16
18
20
22
A
C
B
D
75 °C
65 °C
70 °C
80 °C
85 °C
Item
Description
A
Primary heating demand in litres/hour (l/h)
B
Primary heating supply temperatures
C
Tapping capacity in litres/minute (l/min)
D
Max range
Tapping capacity
DI0000106
40
35
30
25
20
15
10
5
0
2
4
6
8
10
12
14
16
18
20
22
A
B
65 °C
70 °C
75 °C
80 °C
85 °C
Item
Description
A
Return temperature °C
B
Tapping capacity in litres/minute (l/min)
Pressure losses with heat exchanger 40
plates
Heating side (primary)
DI0000107
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
100
300
500
700
900
1100
1300
1500
A
B
C
Item
Description
A
Pressure loss in bar
B
Primary heating demand in litres/hour (l/h)
C
Max range
Pressure losses including ball valves. Additional pressure losses, e.g.
heatmeter with
Qn 1.5
of approximately.
0.05 bar
and other internal/
external fixtures must be included.
40
|
Combi Port E
|