7 Additional installation
7.1 Heat meter or cold/warm water
meter
Hot and cold water meters, and heat meters, can easily be installed
for measuring the water and energy consumption.
Heat meter distance piece
Note
The heat meter to be installed must have following
specifications:
Qn = 1.5
1.5-2 seconds. Construction
length of
110 mm
and
¾"
external threaded connection.
Note
The heat meter distance piece is not suitable for
continuous operation.
CD0000352
The heat meter distance piece is intended to be replaced with a heat
meter to record energy consumption. This is recorded by adding a
heat meter with a fast scanning frequency that fully measures the
volume flow rate every 3-4 seconds, including kWh calculation.
Sensor pocket heat meter
The sensor pocket (M10x1) is available for the flow sensor. The plug
in the delivered condition must first be removed.
1.
Remove plug with an internal hexagon key (
6 mm
).
Cold water meter distance piece
Note
Operating pressure:
PN 10
CD0000354
The cold water meter distance piece (
110 mm x ¾"
) is intended to be
replaced with a water meter that count the units overall cold water
consumption.
Hot water meter distance piece
The hot water meter distance piece is intended to be replaced with a
hot water meter to record water consumption.
CD0000353
18
|
Combi Port E
|
Installation and operation manual