UPM Elite THM701 Скачать руководство пользователя страница 37

TROUBLESHOOTING GUIDE

Specifications:

Number of programs: 7 Day with 4 settings per day

Temperature setting range: 5 – 35°C (41 – 95°F)

Temperature display range: 0 – 50°C (32 – 122°F)

Humidity setting range: 20 to 70%

Humidity display range: 20 to 95%

Battery: 3 x “AA” size batteries

PROBLEM

SOLUTION

Battery symbol (    ) is flashing.

LCD screen is blank.

Heat will not come on.

- Check if the batteries are installed correctly.
- Check if the batteries are fresh and of the correct type.
- Select RESET button on the back of the unit.

- This is an indication that the batteries are running low. Replace with fresh alkaline batteries.
  Note: We recommend to have the batteries replaced at least once a year even if the battery symbol is 
  not flashing.

1) Check and ensure that the thermostat is set to the HEAT or AUTO mode.
2) Check and ensure that the set temperature is higher than the current (room) temperature.
3) You may have to wait up to 5 minutes before the heat will turn on. The thermostat has a built-in time 
    delay to prevent undesirable on/off sequences.
4) After a 5-minute wait, the heating should now be on. Whenever the heating system is running, the
          symbol will be animated.

34

Содержание Elite THM701

Страница 1: ...E L I T E THM701 7 Day Programmable Thermostat TOUCHSCREEN TECHNOLOGY http waterheatertimer org Woods timers and manuals html Noma Garrison...

Страница 2: ...displays house temperature C F Touchscreen LCD display with backlight Displays day hour and minute in 12 or 24 hour clock format Temperature can be set in half d egrees Copy 1 day s program to anothe...

Страница 3: ...eating Cooling 6 Set Humidity 9 Copy Function 9 Set Fan Ventilation System Mode 10 Override Function 11 Hold Function 12 Pre comfort Recovery 13 Usage Monitor 13 Filter Change 13 Battery Changing 14 M...

Страница 4: ...1 Operation and Programming Guide...

Страница 5: ...TIME Full Display includes all icons for reference only 2 HUMIDITY PROGRAM PERIOD STATUS SYMBOLS SYSTEM MODE FAN MODE LOCK WEEKDAYS TABS UP OR DOWN...

Страница 6: ...FAN the fan is running FAN symbol will flash HUMIDITY the humidifier is in use FILTER CHANGE the furnace filter should be changed BATTERY the batteries are low and need to be replaced LOCK the thermo...

Страница 7: ...ith the default Celsius C and THEN change to the Fahrenheit F setting the clock programs and all system settings will be deleted IMPORTANT Getting Started 4 Select C or F Celsius or Fahrenheit Press O...

Страница 8: ...e Press OK to exit 2 1 3 4 Choose 12 or 24 hour clock Press the OPTION tab for 3 seconds Select Option oP1 with the left arrows Choose value with the right arrows 0 12 hour mode Default 1 24 hour mode...

Страница 9: ...t a comfortable temperature typically warmer settings during winter and cooler settings during summer This is the time when you are usually asleep You may choose to set temperature for energy savings...

Страница 10: ...ng P4 Night 2 Select any WEEKDAY the selected day will be underlined 5 Select COPY then other weekday s to copy PROGRAM 1 4 settings 4 Use the UP or DOWN arrows to set the start time and temperature f...

Страница 11: ...ettings with the UP DOWN arrows REPEAT above steps to set the times and temperatures for P2 DAY P3 EVENING and P4 NIGHT To accept settings select OK to undo settings press select CANCEL To continue to...

Страница 12: ...Note The humidifier control only functions when thermostat is in HEAT mode Note Humidity is a manual setting which remains constant it is not pre programmable 2 1 3 This thermostat can copy program s...

Страница 13: ...n the fan is running the FAN symbol will flash System Mode AUTO HEAT OFF COOL AUTO The heating or cooling system will activate according to pre programed temperature settings HEAT The system is in HEA...

Страница 14: ...1 11 2 4 If you wish to select a specific OVERRIDE OFF time different than the start time of the next program period you may select the OVERRIDE UNTIL feature On the MAIN tab press the UP DOWN arrows...

Страница 15: ...urn the HOLD feature off rather than having it lasting indefinitely you may select the HOLD UNTIL day feature Select the HOLD tab The HOLD symbol will flash to indicate HOLD is activated Select the HO...

Страница 16: ...hen displays ACCU Then press any weekday to view the usage hours for that day Press the ACCU tab again to view the USAGE THIS WEEK Accumulated hours starting from Monday Press the ACCU tab again to vi...

Страница 17: ...o replace batteries Select OFF to turn the thermostat to the OFF mode Remove the thermostat from its mounting plate back cover carefully Remove the old batteries and install new ones very quickly Repl...

Страница 18: ...ry which stores all the set programs and thermostat settings if ever the batteries go completely dead or if the batteries are removed from the thermostat for an extended period of time When the batter...

Страница 19: ...OPTIONS which the user can change NOTE Adjust these settings before programming the thermostat because changing certain options will erase all programming There are ten OPTION NUMBERS oP0 to 0P9 Press...

Страница 20: ...3 Key Click Freeze Warning 5 oP4 Pre comfort Recovery 6 oP5 Heat Cycle Rate 7 oP6 HE HG Fan Mode Selection heating 8 oP7 Filter Change Reminder 9 oP8 System Type 10 oP9 C or F Display Optional Setting...

Страница 21: ...r and clicks never sound Value 1 CLICK ON Key click sound enabled warning sound disabled Default Value 2 WARNING ON Freeze warning buzzer enabled key click sound disabled Value 3 CLICK AND WARNING ON...

Страница 22: ...Value 0 HG Mode Use this setting for gas or oil fired furnaces This setting allows the fan operation to be controlled by the heating system not the thermostat This is the correct setting for most sys...

Страница 23: ...8 oP7 Filter Change Reminder Choose how many hours the furnace will be in use before filter change indicator will display Value 0 Disabled Filter change icon will never display Value 1 500 hours Valu...

Страница 24: ...Installation Guide 21...

Страница 25: ...hart on the next page for more details 3 AA size batteries required included Built in protection timing for the air conditioner compressor Warning We recommend consulting a licenced electrician to ens...

Страница 26: ...Conditioner Baseboard Electric Heater 120 240V Heat Pump Single Stage Compatible with Thermostat Yes Yes Yes Yes Yes Some models Some models No No Yes Compatibility Generally equipment with low voltag...

Страница 27: ...ecessary to level the thermostat Masking Tape To wrap the exposed wires temporarily and to label the disconnected wires Power drill with a 3 16 bit If necessary to drill holes on the wall Screwdriver...

Страница 28: ...on an outside wall or next to a door leading outside Exposed to direct light or heat from a lamp sun fireplace or other temperature radiating objects which may cause false readings Near or in direct...

Страница 29: ...o secure the cover Loosen screws holding thermostat to the wall and lift away the thermostat 26 Replacing the Old Thermostat Wiring NOTE WIRING COLORS ARE NOT ALWAYS STANDARDIZED SO IT IS VERY IMPORTA...

Страница 30: ...ckplate and install 3 AA size batteries included Ensure the batteries are installed in the correct direction IMPORTANT Getting Started Remove Backplate Reset Button to restore default settings Install...

Страница 31: ...g the thermostat If you proceed to set the clock and program settings with the default Celsius C and THEN change to the Fahrenheit F setting the clock programs and all system settings will be deleted...

Страница 32: ...B O OPTIONAL JUMPER Wiring Key Regular Wiring G Fan output Y Cool output H1 H2 Humidifier control Rc Common for Cooling and Fan Rh Common for Heating W Heat output 2 Wire Heating Rc Rh Common Rc and R...

Страница 33: ...ling and Fan Rh Common for Heating W Heat output 4 Wire Heating Rc Rh Common Rc and Rh must be connected with jumper 5 Wire Heating 2 separate transformers Heat Cool Rc Rh Common wire separately jumpe...

Страница 34: ...n the thermostat The original humidistat should be removed or set to OFF position Note The 2 humidifier control terminals H1 and H2 are electrically isolated from the Heat Cool terminals Note H1 and H...

Страница 35: ...not touch or short circuit with other terminals Depending on your heating cooling equipment you may need to connect between 2 to 7 wires to the thermostat If you have two R wires then connect each wi...

Страница 36: ...e the back cover from the wall and drill two 3 16 holes in the marked screw positions Insert the wall anchors into the holes completely If necessary use a hammer to tap in lightly Mount the back cover...

Страница 37: ...tton on the back of the unit This is an indication that the batteries are running low Replace with fresh alkaline batteries Note We recommend to have the batteries replaced at least once a year even i...

Страница 38: ...es 4 After a 5 minute wait the air conditioning should now be on Whenever the cooling system is running the symbol will be animated 1 Check if the air conditioning system s main switch is turned on as...

Страница 39: ...rature settings from getting within 3 C 6 F of one another The COOL temperature setting will always be at least 3 C 6 F higher than the HEAT temperature setting For example if the initial COOL program...

Страница 40: ...fective return it with a dated proof of purchase to the retailer from which you purchased it Attention IT IS STRONGLY RECOMMENDED TO HAVE A CERTIFIED ELECTRICIAN ON SITE TO ENSURE THE SAFE INSTALLATIO...

Отзывы: