6) (oP5) - Heat Cycle Rate
Choose the furnace heat cycle (the total ON/OFF intervals that the furnace completes in one hour)
Value 0= OFF (Cycle rate disabled - fixed span)
Value 1= 3 cycles / hour
Value 2= 4 cycles / hour (Default)
Value 3= 6 cycles / hour
Value 4= 8 cycles / hour
7) (oP5) - HE/HG Fan Mode Selection
Depending on your home’s heating system, you may need to change the HE/HG setting
for the fan operation.
Value 0=HG Mode (Use this setting for gas or oil-fired furnaces. This setting allows the fan
operation to be controlled by the heating system, not the thermostat.
This is the correct setting for most systems. (Default)
*Humidifier will not activate the fan
Value 1= HE Mode (You must use this setting for electric furnace heating systems. With this
setting, the thermostat will turn the fan on immediately with the heating system.
*Humidifier will not activate the fan
Value 2= HG Mode (In this HG mode the humidifier will activate the fan)
Value 3= HE Mode (In this HE mode the humidifier will activate the fan)