Choosing a Location for the new Thermostat
Thermostat should be mounted:
Approximately 5’ (1.5 m) from floor.
Near or in a frequently used room, preferably on an inside partitioning wall.
On a section of wall without pipes or duct-work.
Thermostat should NOT be mounted:
Near a window, on an outside wall, or next to a door leading outside.
Exposed to direct light or heat from a lamp, sun, fireplace, or other temperature-radiating objects
which may cause false readings.
Near or in direct airflow from heat registers and air conditioners.
Near concealed pipes and chimneys.
In areas with poor air circulation, such as behind a door or in an alcove.
25
Note: Do not operate the cooling system when outside temperature is below 10°C (50°F) to avoid
damaging the compressor.