![Unitek BAMOCAR-PG-D3-700-900 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/unitek/bamocar-pg-d3-700-900/bamocar-pg-d3-700-900_manual_4037715015.webp)
Basic - information
Version: 2020 / V3
Seite: 14
BAMOCAR-PG-D3-700-900
1.13
Risks
The manufacturer aims to keep the remaining risks emanating from the unit as low as possible by means
of constructive, electrical, and software measures.
In the field of drive engineering the following known remaining risks must be considered regarding the
risks arising from machines, vehicles, and installations.
Impermissible movements
caused by:
•
failure of safety watchdogs or switched-off safety watchdogs during commissioning or repair
works
•
software errors in upstream controls, errors in bus systems
•
non-monitored hardware and software errors in actuating elements and connecting cables
•
inverted sense of control
•
faults during the parameter setting and wiring
•
limited response time of the control features. Ramps, limits
•
operations not permitted in the specifications
•
electromagnetic interferences
•
electrostatic interferences, lightning strikes
•
failure of components
•
failure in the brakes
Dangerous temperatures
caused by:
•
faults during the installation
•
faulty connections, bad contacts, aging
•
faults in the electric safety system, incorrect types of fuses
•
operations not permitted in the specifications
•
negative climatic conditions, lightning strikes
•
failure of components
Dangerous voltages
caused by:
•
faulty earthing of the unit or motor
•
faulty insulation monitoring
•
faulty connections, bad contacts, aging
•
faulty potential isolation, failure of components
•
conductive contamination, condensation
Dangerous fields
The units, the inductive and capacitive accessories as well as the power
wiring can generate strong electric and electromagnetic fields. These
fields may be dangerous for persons having electronic medical aids or
appliances (e.g. cardiac pacemakers). Sufficient distance to these
electrical parts must be observed.
Any assembly area must be indicated and labelled accordingly.
Содержание BAMOCAR-PG-D3-700-900
Страница 20: ...Mechanical installation Version 2020 V3 Seite 19 BAMOCAR PG D3 700 900 2 2 Dimensions BAMOCAR PG D3 700 900...
Страница 23: ...Electrical installation Version 2020 V3 Seite 22 BAMOCAR PG D3 700 900 3 2 Circuit diagramm...
Страница 24: ...Electrical installation Version 2020 V3 Seite 23 BAMOCAR PG D3 700 900...
Страница 25: ...Electrical installation Version 2020 V3 Seite 24 BAMOCAR PG D3 700 900 3 3 Connection diagramm...