background image

malfunction or even bring harm to persons and properties. To avoid danger, if a machine failure 
occurs, ask the manufacturer or professionals to repair it. 

Do not install and use the air conditioning in the bathroom or other humid environments.

Do not pull the plug to turn off the machine.

Do not place cups or other objects on the body to prevent water or other liquids from spilling into
the air conditioning.

Do not use insecticide sprays or other flammable substances near the air conditioning.

Do  not  wipe  or  wash  the  air  conditioning  with chemical  solvents  such  as  gasoline  and  alcohol.
When you need to clean the air conditioning, you must disconnect the power supply, and clean it
with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.

The appliance can be used by children aged from 8 years and above and persons with reduced
physical,  sensory  or  mental  capabilities  if  they  have  been  given  supervision  or  instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children shall
not  play  with  the  appliance.  Cleaning  and  maintenance  shall  not  be  made  by  children  without
supervision.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.

The appliance shall be installed in accordance with national wiring regulations.

Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

Transportation, marking and storage for units 

1. Transport of equipment containing flammable refrigerants
Compliance with the transport regulations 
2. Marking of equipment using signs
Compliance with local regulations 
3. Disposal of equipment using flammable refrigerants
Compliance with national regulations 
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions. 
5. Storage of packed equipment
Storage package protection should be constructed such that mechanical damage to the equipment 

inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of 
equipment permitted to be stored together will be determined by local regulations. 

Содержание UPC-8029

Страница 1: ...INSTRUCTIONS MANUAL UPC 8029 LOCAL AIR CONDITIONER Read and save these instructions for future reference...

Страница 2: ...Adjustment IV Control Setting V Drainage Instructions VI Maintenance VII Troubleshooting VIII Appendix Please read these instructions before use and repair The drawings provided in this manual may no...

Страница 3: ...in the use of flammable refrigerants 12 All working procedure that affects safety means shall only be carried by competent persons Notes The air conditioning is only suitable for indoor use and is not...

Страница 4: ...nd understand the hazards involved Children shall not play with the appliance Cleaning and maintenance shall not be made by children without supervision If the supply cord is damaged it must be replac...

Страница 5: ...e control panel beautiful and fashionable with high quality remote control It adopts a user friendly remote control design Air filtration capability Timing switch function Protection function of autom...

Страница 6: ...ht position and the air conditioning should be placed on a flat surface Do not install and use the air conditioning in the bathroom or other humid environments 1 1 Install the heat pipe assembly as sh...

Страница 7: ...mponents of the assembly 1 2 Install the window sealing plate assembly 1 3 Install the body 1 Move the machine with installed heat pipe and fittings before the window and the distance between the body...

Страница 8: ...Up Key 3 Down Key 4 Display Window 5 Fan Speed Selection Key 6 Mode Selection Key 7 Power Key When the machine is powered on for the first time the buzzer will play power on music and then the machine...

Страница 9: ...timing in the case of power off press the key to open timing Press the key when the timing symbol flashes press up and down key to select the required timing value Timing values can be set in 1 24 hou...

Страница 10: ...t to sewer or other drainage area to empty the water details see Drainage Instructions at the end of this chapter After the water is emptied the machine will automatically return to the original state...

Страница 11: ...water plug and tighten the drainage cover Notes 1 Restart the machine after the water plug and drainage cover are installed otherwise condensate water of the machine will flow to the floor or the car...

Страница 12: ...ing to remove the EVA filter screen as shown in the above figure 2 Put the EVA filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean Unit Storag...

Страница 13: ...being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigerat...

Страница 14: ...safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If th...

Страница 15: ...cumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used 6 Leak detectio...

Страница 16: ...not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them Cylinders shall be kept upright Ensure that the refrigerat...

Страница 17: ...special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated an...

Страница 18: ...ditioning by yourself Unqualified repair will lead to failure of the warranty card and may cause damage to users or their properties Problems Reasons Solutions The air conditioning does not work There...

Страница 19: ...r The remote control is not aligned with the direction of the remote control receiver Batteries are dead Replace batteries Displays E1 The pipe temperature sensor is abnormal Check the pipe temperatur...

Страница 20: ...collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product c...

Отзывы: