The air inlet or outlet is blocked.
Clear obstructions.
Big Noise
The air conditioning is not placed on
a flat surface.
Put the air conditioning on a flat and hard
place (to reduce noise).
compressor
does not work.
Overheat protection starts.
Wait for 3 minutes until the temperature is
lowered, and then restart the machine.
The remote
control does not
work.
The distance between the machine
and the remote control is too far.
Let the remote control get close to the air
conditioning, and make sure that the
remote control directly faces to the direction
of the remote control receiver.
The remote control is not aligned
with the direction of the remote
control receiver.
Batteries are dead.
Replace batteries.
Displays 'E1'.
The pipe temperature sensor is
abnormal.
Check the pipe temperature sensor and
related circuitry.
Displays 'E2'
The room temperature sensor is
abnormal.
Check the room temperature sensor and
related circuitry.
Note: If problems not listed in the table occur or recommended solutions do not work, please contact the
professional service organization.
Appendix
Fuse Parameters
Type: FSD or 50F
Voltage: 250V
Current: 3.15A
Schematic Diagram
All the technical and specific parameters,please refer to product nameplate.
Due to continuous improvement,we reserve the right to change some design without any notice.
Condenser
Compressor
Evaporator
Capillary