I. Attention Matters 

Warnings: 

1. Do not use means to accelerate the defrosting process or to clean, other than those recommended by
the manufacturer. 
2. The appliance shall be stored in a room without continuously operating ignition sources (for example:
open flames, an operating gas appliance or an operating electric heater.) 
3. Do not pierce or burn.
4. Be aware that refrigerants may not contain an odour.
5. Appliance shall be installed, operated and stored in a room with a floor area larger than 7 m2
7. Keep any required ventilation openings clear of obstruction;
8. Servicing shall be performed only as recommended by the manufacturer.
9. The appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specified for operation. 
10. Any  person  who  is  involved  with  working  on  or  breaking  into  a  refrigerant  circuit  should  hold  a
current  valid  certificate  from  an  industry-accredited  assessment  authority,  which  authorizes  their 
competence  to  handle  refrigerants  safely  in  accordance  with  an  industry  recognized  assessment 
specification.     
11. Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the supervision 
of the person competent in the use of flammable refrigerants.   
12. All working procedure that affects safety means shall only be carried by competent persons.

Notes: 

The air conditioning is only suitable for indoor use, and is not suitable for other applications.

Follow  local  grid  interconnection  rules  while  installing  the  air  conditioning  and  ensure  that  it  is
properly grounded. If you have any question on electrical installation, follow the instructions of the
manufacturer, and if necessary, ask a professional electrician to install it.

Place the machine in a flat and dry place and keep a distance of above 50cm between the machine
and the surrounding objects or walls.

After the air conditioning is installed, ensure that the power plug is intact and firmly plugged into the
power outlet, and place the power cord orderly to prevent someone from being tripped or pulling
out the plug.

Do not put any object into the air inlet and outlet of the air conditioning. Keep the air inlet and outlet
free from obstructions.

When drainage pipes are installed, ensure that the drainage pipes are properly connected, and are
not distorted or bended.

While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to
avoid damaging wind-guide strips.

When moving the machine, make sure that it is in an upright position.

The machine should stay away from gasoline, flammable gas, stoves and other heat sources.

Don't disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a machine

Содержание UPC-8029

Страница 1: ...INSTRUCTIONS MANUAL UPC 8029 LOCAL AIR CONDITIONER Read and save these instructions for future reference...

Страница 2: ...Adjustment IV Control Setting V Drainage Instructions VI Maintenance VII Troubleshooting VIII Appendix Please read these instructions before use and repair The drawings provided in this manual may no...

Страница 3: ...in the use of flammable refrigerants 12 All working procedure that affects safety means shall only be carried by competent persons Notes The air conditioning is only suitable for indoor use and is not...

Страница 4: ...nd understand the hazards involved Children shall not play with the appliance Cleaning and maintenance shall not be made by children without supervision If the supply cord is damaged it must be replac...

Страница 5: ...e control panel beautiful and fashionable with high quality remote control It adopts a user friendly remote control design Air filtration capability Timing switch function Protection function of autom...

Страница 6: ...ht position and the air conditioning should be placed on a flat surface Do not install and use the air conditioning in the bathroom or other humid environments 1 1 Install the heat pipe assembly as sh...

Страница 7: ...mponents of the assembly 1 2 Install the window sealing plate assembly 1 3 Install the body 1 Move the machine with installed heat pipe and fittings before the window and the distance between the body...

Страница 8: ...Up Key 3 Down Key 4 Display Window 5 Fan Speed Selection Key 6 Mode Selection Key 7 Power Key When the machine is powered on for the first time the buzzer will play power on music and then the machine...

Страница 9: ...timing in the case of power off press the key to open timing Press the key when the timing symbol flashes press up and down key to select the required timing value Timing values can be set in 1 24 hou...

Страница 10: ...t to sewer or other drainage area to empty the water details see Drainage Instructions at the end of this chapter After the water is emptied the machine will automatically return to the original state...

Страница 11: ...water plug and tighten the drainage cover Notes 1 Restart the machine after the water plug and drainage cover are installed otherwise condensate water of the machine will flow to the floor or the car...

Страница 12: ...ing to remove the EVA filter screen as shown in the above figure 2 Put the EVA filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean Unit Storag...

Страница 13: ...being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigerat...

Страница 14: ...safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If th...

Страница 15: ...cumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used 6 Leak detectio...

Страница 16: ...not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them Cylinders shall be kept upright Ensure that the refrigerat...

Страница 17: ...special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated an...

Страница 18: ...ditioning by yourself Unqualified repair will lead to failure of the warranty card and may cause damage to users or their properties Problems Reasons Solutions The air conditioning does not work There...

Страница 19: ...r The remote control is not aligned with the direction of the remote control receiver Batteries are dead Replace batteries Displays E1 The pipe temperature sensor is abnormal Check the pipe temperatur...

Страница 20: ...collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product c...

Отзывы: