Will Not Begin Cycle
Possible Problem
Item to Check
Remarks
No power to the machine
Verify that the Power Indicator is lit
and the CPC screen is operational.
Follow the procedures under
“Interface Not Functioning”
Shutter Door is not closed
entirely
The Shutter Door must be closed in
order in order to place the machine
in Run Mode.
Always either completely open or
completely close the Shutter Door.
Drive error
Check Drive Keypad for error code.
Refer to the instruction manual for
the drive that was supplied with the
machine or contact AXYS for
support.
Loose wire or defective
component
Turn the main disconnect to the
“Off” position and carefully check
and retighten electrical connections
beginning at the main disconnect.
If you are certified to work with high
voltage AC, re-energize the
Disconnect and follow the voltage
paths until you find the problem.
Premature System Halt
Possible Problem
Item to Check
Remarks
No power to the machine
Verify that the Power Indicator is lit
Follow the procedures under
“Interface Not Functioning”
Drive error or overload
Check Drive Keypad for error code.
Refer to the instruction manual for
the drive that was supplied with the
machine or contact AXYS for
support.
Human error
Attempting to open the Shutter
Door while the machine is running
may result in the cycle being
canceled.
The Stop Button may have been
accidentally pressed.
If the cycle timer has reset, human
error is likely the problem. If the
machine is stopped and the timer is
still running, human error must be
discounted.
E-Stop activated
Check the CPC Touch Screen to
determine if the E-Stop has been
activated.
If the E-Stop has been activated the
timer will display the remaining time.
Proceed to Manual Mode Screen to
determine time remaining and finish
the current process.
Loose wire or defective
component
Turn the main disconnect to the
“Off” position and carefully check
and retighten electrical connections
beginning at the main disconnect.
If you are certified to work with high
voltage AC, re-energize the
Disconnect and follow the voltage
paths until you find the problem.
Содержание CPC4000
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......