3.7.1 CODABAR COUPLING
CODABAR COUPLING
ON OFF*
◆
SET INSERT DATA
INSERT DATA-ON
INSERT DATA-OFF
ABC-Codabar and CX-Codabar have certain rules regarding the Stop
Character of first bar code and the stop character of second bar code while in
conjunction, while Codabar- Coupling is enabled, the data from any two
Codabar bar codes can be coupled into one set of data without any limitations
Between the Stop character of first bar code and the Start characters of second
bar code. The Start and Stop characters associated with each bar code will be
sent.
◆
The data can be any alphanumerics of FULL ASCII Table
.
(
Appendix B
)
ADJACENT REQUIRED
ON OFF*
If CODABAR ADJACENT is enabled, the scanner will only read two adjacent
Codabar bar codes; a single bar code will not be read.
NOTE:
1. Both ABC-Codabar and CX-Codabar can be enabled together, except when
Codabar-Coupling is also enabled.
2. If ABC-Codabar, CX-Codabar, and Codabar-Coupling are all enabled at the
same time, the scanner will read only Codabar- Coupling, that is,
ABCCodabar,CX-Codabar will be considered coupling formats
SETTING PROCEDURE – SET INSERT DATA
STEP 1
- Scan:
Scan SET INSERT DATA.
STEP 2
- Scan: Scan any combination of alphanumeric characters from FULL
ASCII Table.
(
Appendix B
)
STEP 3
- Scan: SET INSERT DATA..
RESET
P023$
Note:
1. The scanner will beep three times as a reminder that a setting is
not yet complete.
2. If you make a mistake, forget a step, etc., Scan RESET to start
again.