111
13
Options
111
Options
Chapter
13
■
Equivalent circuit
Output
Input
Caution
●
Do not apply voltage into the signal input circuit from outside.
●
An external element must be an element in which Ic=10mA or more can be applied.
●
An external element leak must be 30
μ
A or below.
Output
COM
+24VRTN
COM
Input
+24V
F325
Sink type
PLC input unit and so on
Plus common type
A2 to A12
B2 to B13
A1, B1
+5V
Vceo=30V(max)
Ic=50mA(max)
●
Internal transistor condition
Output data
Negative
Positive
0
OFF
ON
1
ON
OFF
●
Output pin level
Output data
Negative
Positive
0
H
L
1
L
H
In accordance with logic selection (B14pin)
F325
PLC output unit and so on
Sink type
Output
COM
Ic=
Input
COM
A1, B1
A14, B14
+5V
Open-circuit
OFF
Short-circuit
ON