ARE-M Series 24V Chargers, Single Phase
Introduction
PM990-1070-24, Issue 12
1-3
TABLE 1-1 MODEL DESIGNATION
DC VOLTAGE & CURRENT
ARE-M02406A (AC Input Voltage: 120V/208V/240V)
ARE-M02412A (AC Input Voltage: 120V/208V/240V)
ARE-M02425A (AC Input Voltage: 120V/208V/240V)
ARE-M02450A (AC Input Voltage: 120V/208V/240V/480V)
ARE-M024100A (AC Input Voltage: 120V/208V/240V/480V)
AC Input Voltage / Breaker
A
120V - 60 Hz Standard Capacity AC Breaker
B
208V - 60 Hz Standard Capacity AC Breaker
C
240V - 60 Hz Standard Capacity AC Breaker
D
480V - 60 Hz Standard Capacity AC Breaker (50 A & 100 A only)
1
120V - 60 Hz High Capacity AC Breaker
2
208V - 60 Hz High Capacity AC Breaker
3
240V - 60 Hz High Capacity AC Breaker
4
480V - 60 Hz High Capacity AC Breaker (50 A & 100 A only)
AC Protection
1
Not Required (Standard)
2
480/240 VAC Input Lightning Arrestor
3
240/208/120 VAC Input Lightning Arrestor
DC Circuit Breaker
1
Standard Capacity AC Breaker/ Standard Capacity DC Breaker
2
Standard Capacity AC Breaker/ High Capacity DC Breaker
3
Standard 480V AC Breaker/ Standard Capacity DC Breaker
4
Standard 480V AC Breaker/ High Capacity DC Breaker
5
High Capacity AC Breaker/ Standard Capacity DC Breaker
6
High Capacity AC Breaker/ High Capacity DC Breaker
7
High 480V AC Breaker/ Standard Capacity DC Breaker
8
High 480V AC Breaker/ High Capacity DC Breaker
A
Telecom Standard Capacity AC Breaker/ Standard Capacity DC Breaker
B
Telecom Standard 480V AC Breaker/ Standard Capacity DC Breaker
C
Telecom High Capacity AC Breaker/ Standard Capacity DC Breaker
D
Telecom High 480V AC Breaker/ Standard Capacity DC Breaker
DC Protection
1
None (Standard)
2
MOVs
Blocking Diode
1
None (Standard)
2
Yes (Negative Leg)
Temperature Compensation
1
None (Standard)
2
Battery Temperature Compensation (Temperature Sensor with 25' lead)
Control Wiring
1
Floating Ground (Standard) - PVC
2
Floating Ground Switchboard - SIS
A
Telecom - Positive Ground - PVC
B
Telecom - Negitive Ground - PVC
Individual Alarm Relays
1
Utility - AC Fail, High Voltage, Rectifier Fail
2
Utility - AC Fail, High Voltage, Rectifier Fail, Hi VDC, Low VDC,
NO Charge, GND+, GND-, Summary
3
Utility - AC Fail, High Voltage, Rectifier Fail, w/Ground Enable Switch
4
Utility - AC Fail, High Voltage, Rectifier Fail, Hi VDC, Low VDC,
NO Charge, GND+, GND-, Summary, w/Ground Enable Switch
A
Telecom - AC Fail, High Voltage, Rectifier Fail
B
Telecom - AC Fail, High Voltage, Rectifier Fail, Hi VDC, Low VDC,
NO Charge, Summary
Control Board
1
Utility (Standard)
(Discontinued)
2
Utility Alarm Lights - AC, Summary Alarm, HVA, LNA, NCA, ACF, GND+, GND-
A
Telecom (Standard)
(Discontinued)
B
Telecom Alarm Lights - AC, Summary Alarm, HVA, LNA, NCA, ACF
Mounting
1
Wall 19"
3
Relay 19"
4
Relay 23"
5
Floor Mount
6
Floor Mount with Drip Shield
Packaging
1
Domestic (Standard)
2
Export
3
None (For relay rack installation only)
DNP3 Communications Port
1
No Port (Standard)
2
DNP3 Ethernet 4 foot cable
3
DNP3 Ethernet 2 foot cable
4
DNP3 Ethernet 25 foot cable
5
DNP3 Ethernet 50 foot cable
Special Instructions
1
No
2
Yes
ARE-M
2406
A
2
2
1
1
2
1
1
3
1
1
1
1
Base Model
S Build Number