35
Daily UV Cleanup Procedure
NOTE:
Uninet
recommends the inspection of the Safety Guards every three (3) months!
1.
Reverse the input and output hose from the pump and depress the coating fill button until the hose
is empty.
2. If your
iColor coater
is equipped with the optional Automatic Coating Sensor, the lack of coating
in
the nip will cause the pump to turn on and put the coating in the hose back into the bucket. If you
are using the manual pump, you must press F9 from the pump screen.
3. Turn the UV Lamp OFF! Turn the Belt OFF!
4. Remove the excess coating from the Coating Unit by using the Vac. or Bulb Sy-ringe
5. Remove the two hoses from the Coating Unit and place into a plastic bucket with rags (to
prevent
dripping).
NOTE:
It is Important that you remove the hose kit prior to cleaning the Coating Unit as
coating
and/or cleaner may flow out of the hose nozzle.
6. Pour a small amount of
UV Klean
into the coating unit and run
it
for 30 seconds. Run for another
30 seconds to clean the rollers. Turn OFF the belt, open the safety guard and
remove
UV Klean
from the nip with the Vac or Bulb Syringe. Repeat until all coating is
removed.
CAUTION:
Never put the Vac nozzle or Bulb Syringe into the nip with the machine run-ning as
damage to the rollers can occur, which is NOT covered by the roller warranty!
7. Remove and clean the coating drip pan with
UV Klean.
8. Remove and clean the doctor blade with
UV Klean.
9. While you have the Doctor Blade and the Drip Pan removed, completely clean the Impression roller
with
UV Klean
. Reinstall drip pan & doctor blade.
10. Turn the coating unit controls to the
“END OF DAY POSITION”
to prevent flat spots on the rollers.
11. Turn the Main Power Switch OFF!