Setting the “Optional” Automatic UV Coating Sensor
NOTE:
If your
iColor coater
is equipped with the Automatic Coating Sensor proceed with
setting the coating sensor. If it is NOT, proceed to the next page.
Your Automatic Coating Sensor is preset in the factory. Before you begin the coating process it is im-
portant that you test the settings and make the appropriate adjustments for your current job.
1. Turn the Main
iColor coater
Power Button to the ON position.
2.
If the sensor light is AMBER:
a. Turn ON the auto pump by pressing F7 in the pump screen
(
Note:
The “optional” coating sensor will not operate if the machine is not running)
b. Turn ON the belt by pressing F5 in the belt screen
c.
Carefully watch as the Coating Unit is filled with coating.
i.
If the coating automatically stops near the imaginary fill line, NO adjustment is required.
ii.
If the coating does not automatically stop once it reaches the imaginary fill line, immediately
open the front guard to stop the belt and auto pump.
a. With the safety cover open, adjust the sensor, by turning the screw clockwise with a
small flat head screwdriver until the light turns OFF
iii. If the coating stops before it reaches the imaginary fill line.
a. Lift the safety cover.
b. Adjust the sensor, by turning the screw counterclockwise with a small flat head screw
-
driver, until the light turns AMBER.
3.
If the sensor light is OFF:
a. Lift the safety cover.
b.
Adjust the sensor, by turning the screw counterclockwise with a small flat head screwdriver, until
the AMBER light turns on.
c. Return to step 2a and continue setting the coating sensor.
Figure - UV Coating Sensor
Sensor Adjustment Screw
Figure - Coating Fill Line
Imaginary Coating Fill Line