63
Freq Avoids
– This allows you to review Avoided Frequencies or Stop Avoiding all Frequencies
for Searching and Close Call search.
Temporary Avoids appear reversed in the display -
.
Stop All Avoiding.
See also Avoiding Frequencies, page 66.
At
Confirm?
Press
E/yes
or
./no
.
Rvw Search Avoid
Scroll to Frequency and press
E/yes
to Stop Avoiding.
Broadcast Screen
– Automatically ignores transmissions that are on common broadcasts, paging
systems, and other annoyance radio sources during Custom Search, Quick Search, or Close Call
Search. The default setting is
Pager On
.
Set All Band On/Off.
Turns Broadcast Screen
On
or
Off
for All Bands.
Set Each Band
Scroll to each
Band
and press
E/yes
to enable or disable.
Program Band
Band 0-9
Select for each Close Call Band and other searches.
Set Lower Limit
- Input the lower frequency limit.
Set Upper Limit
- Input the upper frequency limit.
Press
Menu
to return and repeat for each band as needed.
Repeater Find
– Sets whether the scanner tries to tune to a repeater output frequency when it
detects a transmission on a repeater input frequency, in Search and Close Call modes. Turning
this feature on can let you hear both sides of the conversation on the output frequency. The
default setting is
Off
.
On
or
Off
Set Delay Time
– Determines how long the scanner waits after a transmission ends before
resuming Quick Search and Close Call Search operations.
A negative delay will force a resume after that number of seconds.
The default setting is
2
seconds.
-10, -5, 0, 1, 2, 3, 4, 5, 10,
or
30
sec.
Set Attenuator
– This controls the attenuator for Quick Search, and Close Call operations by
about 20dB. The default setting is
Off
.
On
or
Off
See also Search Attenuation, page 66.
Set Audio AGC
– This allows you to turn AGC (Automatic Gain Control) on or off for Quick Search
and Close Call modes. The default settings are
Off
.
Analog.
Press
E/yes
to toggle
On
or
Off
.
Digital.
Press
E/yes
to toggle
On
or
Off
.
P25 Waiting Time
– This setting gives the scanner time to determine if frequencies have digital
or analog transmissions. During this time, the scanner will evaluate the received signal and, if
it detects digital data, will open squelch immediately. If digital is not detected before the delay
expires, the scanner will open squelch at the end of this delay. This is to prevent “false decode”
problems. The default setting is
400
ms.
0
to
1000
ms
Note: Any analog transmissions will lose the first part of the transmission, up to the wait
time you set here.
Содержание UBCD436-PT
Страница 10: ......
Страница 105: ...95 ...
Страница 106: ...96 ...
Страница 108: ... 2015 Uniden Australia Pty Ltd Printed in Vietnam U01UB376AZA ...