40
Scroll to
Review/Edit System
and press
E/yes
.
Scroll to the
System
you want to edit and press
E/yes
.
Scroll to
Edit Site
and press
E/yes
.
To Create a New Site,
scroll to New Site and press
E/yes
.
To Edit an Existing Site,
scroll to the Site and press
E/yes
.
Note: Not all options will appear for all sites.
Edit Name
Set Modulation
P25 Threshold Mode
Set Site Quick Key
Set Attenuator
P25 Threshold Level
Set Site Type
Set Avoid
delete Site
Edit Band Plan
Set Location Information
New Site
Set frequencies
P25 Waiting Time
Edit Name
See Data Naming, page 25.
Set Site Quick Key -
This assigns a quick key to the Site and the scanner will scan the Site when
the key is enabled. The default setting is
.
(no quick key). If you don’t assign a quick key to a Site,
it will always be scanned unless you Avoid it.
0-99
or
.
for no quick key.
Note: Pressing the first number of a 2-digit quick key will get you closer, 1 for 10, 2 for 20,
etc., then scroll to second digit.
Set Site Type (EDACS Only)
– EDACS Wide is the same as EDACS Standard and use a 9600
baud control channel. EDACS Narrow-band sites use a 4800 baud control channel.
Wide (Standard)
or
Narrow
. The default setting is
Wide
.
Edit Band Plan (Motorola/P25 Only)
– Band plans are required so the scanner can correctly
determine the voice channel frequencies.
P25 Systems.
Explicit mode systems (which comprise most systems in use) include all
information needed to determine voice frequencies on the control channel, leave all entries
blank. The system will automatically detect the band plan and fill in the entries. Implicit
systems need you to supply the systems band plan with the
Custom
option for the scanner
to correctly determine voice frequencies.
Select Plan
- Scroll to each
Band Plan 0-9
,
A-F
, and press
E/yes
.
Input Base Freq
- Enter the base frequency press
E/yes
.
Input Spacing
- Enter the step size and press
E/yes
.
Press
Menu
to return and repeat for each band plan as needed.
Motorola Systems
800/900 Standard
or
800 Splinter
The scanner will use the regular Motorola band plan.
Custom (rebanded) Motorola/VHF/UHF Systems.
Custom band plans require that you
enter both a lower and an upper base frequency value.
The lower base frequency (or base)
is always the base frequency as provided in the Radio Reference Database.
Use this Excel spreadsheet to calculate the upper base frequency value located at:
http://info.uniden.com/twiki/pub/UnidenMan4/CalculatingUpperBaseFrequencies/
CustomBandPlanCalculator.xls
Содержание UBCD436-PT
Страница 10: ......
Страница 105: ...95 ...
Страница 106: ...96 ...