To select the RS-232 baud rate (other than the default 9600* baud) you must
link one (or more) of the COMPUTER connector pins 15, 16 and 17 to
ground (pin 7).
Pin 15
Pin 16
Pin 17
Baud Rate
GND
NC
GND
300
NC
GND
NC
1200
NC
GND
GND
2400
GND
GND
NC
4800
NC
NC
NC
9600*
NC
NC
GND
19200
GND
NC
NC
38400
GND
GND
GND
76800
NC = Not connected.
GND = connected to ground.
Note that pin 14 is reserved.
7.3
Communications (STARLOG) Protocol
This section describes the communications protocol common to all
STARLOG products. See Appendix B
Starlog Protocol Command List for a
complete list of STARLOG protocol commands.
7.3.1
Scan Synchronised RS-232 Communication
At the end of every scan (5 seconds usually) the logger will check to see if the
computer interface is connected. If the interface is connected, the logger
sends a prompt to the interface (host computer). This prompt is an ASCII
asterisk followed by a carriage return (CR).
The logger then waits 0.5 second for a request from the host computer. If no
request is received by the logger, the logger powers down (switches off) until
the next scan (5 seconds usually).
While the logger is communicating with the computer, it will remain active
(in high power mode). However, any logger scans that are due will be
processed simultaneously with ongoing communications.
PROLOGGER Hardware
COMPUTER COMMUNICATION 35
Содержание Starlog Prologger 7001
Страница 1: ...STARLOG PROLOGGER Hardware Model 7001 Revision 33 Firmware User Manual Revision A 6261 May 1999...
Страница 6: ......
Страница 60: ......
Страница 64: ......
Страница 67: ...02 PROM Verify Fail 03 Mirror Fail 04 Bad checksum in RAM firmware PROLOGGER Hardware 3...
Страница 68: ......