Low Pressure Application
Low pressure solenoid:
GOYEN 10BL2-CNBNT-61D7 direct acting solenoid.
Maximum pressure:
70kPa.
Minimum pressure:
0kPa.
Recommended
minimum:
10kPa.
Spare parts kits:
GOYEN KM1423.
Pump:
Optional pump (same as drain pump) if gravity feed not
possible.
Inlet Hose:
12.5mm heavy-duty flexible hose, 2 metres long to connect
to tank.
Two stainless steel hose clamps supplied.
Inlet filter installed upstream of solenoid.
Drain Pump
Type:
Marine bilge pump. Located in pan. Cable length 2 metres.
Power:
12 volts @ 1.2 amps.
Capacity:
Maximum 20 litres/minute.
Housing:
PVC enclosure attached to inside of pan.
Drain Hose:
12.5mm hose can be connected. Not normally supplied.
Power Supply
Power supply:
Maximum 0.3 ampere hour/day with daily level reset.
Battery:
Model 6907B 12 volt, 7 ampere-hour sealed lead acid
battery.
Charger:
Model 6904B 12 volt, 2 watt solar panel on enclosure roof.
Regulated by circuit in level control system.
Automatic Evaporation System
SPECIFICATIONS AND DETAILS 9
This page intentionally left blank.
UNIDATA
10 SPECIFICATIONS AND DETAILS