background image

2.2

Automatic Evaporation Recording

Model 6706A Aluminium Enclosure

Dimensions:

320mm x 300mm x 750mm (Width x Depth x Height).

Vertically sliding front door. With hole for (purchaser
supplied) padlock.

Material:

2mm aluminium sheet. Powder coat finish.

Mounting:

1300mm long galvanised steel pipe, 40mm diameter with
cap. Two U-bolt assemblies to suit pipe.

Model 6529G Stillwell Assembly

Dimensions:

370mm high, 150mm diameter, with sealed bottom.

Material:

PVC pipe.

Stillwell Cap:

PVC Cap predrilled for float system and 6541. Cap rotates
to allow rear of 6541 to be visible.

Connector:

Bottom fitting for 12.6mm hose to evaporation pan.

Automatic Evaporation System

SPECIFICATIONS AND DETAILS 7

Model 6541-31
Precision water level instrument
with display. Rotate 90° to view
and check float pulley.

6541-31/C
Integrated Micrologger
(optional).Connect to
computer with a
9 pin cable.

Model 6706A
Aluminium enclosure for evaporation
system. “U” bolt to post.

Model 6529A-2
PVC stillwell assembly.

Model 6907B
12V battery.

Model 6529-1
Level control module.

Model 6529-1
Refill solenoid with filter.

Model 6904B
Solar Panel on
top of cabinet.

Model 6529A-3
Float system inside.
PVC 115mm float,
line, counterweight,
and offset guide pulley.

Hose:

12.6mm heavy-duty flexible hose, 1.8 metres long.

Two stainless steel hose clamps supplied.

Hose guide:

PVC pipe, 40m diameter, and 1300mm long.

Model 6541 Water Level Instrument

See the User Guide for the Model 6541 instrument for specifications.

Float system:

Float pulley 100mm circumference. Offset pulley fitted.

Float 115mm PVC. Counterweight -160 grams.

Floatline 0.4mm diameter stainless steel. 690 mm long.

2.3

6529E Automatic Evaporation Recording And Level
Control

6912BR/12 Level Controller

Circuit card with relays to operate fill solenoid and drain pump, and a solar
charge regulator for battery.

Enclosure:

UV stabilised polycarbonate, IP67.

Size:

125mm x 75mm x 75mm (L x W x D).

Terminals:

Pluggable terminal strip with terminals for fill solenoid,
drain pump, solar panel, battery and test.

Cables:

1m cable to data logger terminal block of 6541-31/C.

0.3m battery leads.

Fill Solenoid

Type:

Solenoid valve with 10mm bore and nitrite seals. Cable
length 0.5m.

Power:

12 volts @ 1.2 amps.

High Pressure Application

High Pressure

Solenoid:

Goyen 10BWJ-CNBNT-61D7.

Maximum pressure 1000kPa.

Minimum recommended pressure 10kpa.

Spare parts kit:

GOYEN KM1664.

UNIDATA

8 SPECIFICATIONS AND DETAILS

Содержание STARLOG 6529

Страница 1: ...may be reproduced transmitted transcribed stored in a retrieval system or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical...

Страница 2: ...he Water Level Instrument 23 5 3 5 Set And Test The System 24 5 4 The Level Control System 25 5 4 1 Overview 25 5 4 2 Level Control Module 26 Automatic Evaporation System i 5 4 3 Fill System 26 5 4 4...

Страница 3: ...een pan evaporation and site conditions This is required for evaporation and evapo transpiration studies and modelling An optional telemetry system can be connected to the datalogger Landline cellular...

Страница 4: ...E or later and are supplied on disk with initial releases of the instrument Alternatively you can obtain this update from the technical support section on the UNIDATA web site www unidata com au Refer...

Страница 5: ...ngs Intake Bulkhead fitting for 12 5mm ID hose Connects level gauge to stillwell Refill Bulkhead fitting for 12 5mm ID hose Connects level control system to pan Pan weight 12kg Mounting Timber frame 1...

Страница 6: ...el on top of cabinet Model 6529A 3 Float system inside PVC 115mm float line counterweight and offset guide pulley Hose 12 6mm heavy duty flexible hose 1 8 metres long Two stainless steel hose clamps s...

Страница 7: ...rain Pump Type Marine bilge pump Located in pan Cable length 2 metres Power 12 volts 1 2 amps Capacity Maximum 20 litres minute Housing PVC enclosure attached to inside of pan Drain Hose 12 5mm hose c...

Страница 8: ...rable with a manual pan Automatic Evaporation System EVAPORATION MONITORING TECHNIQUES 11 3 1 Using Evaporation Pan Data The daily total evaporation can vary from 0 on a cool and misty day to more tha...

Страница 9: ...sites and data quality is compromised Water level too high will result in rainfall splashing or blowing from the tank when it is near full and overflowing when it is full Water level below the referen...

Страница 10: ...tomatic Evaporation System SITE REQUIREMENTS AND LAYOUT 15 4 1 1 Water Supply The evaporation pan is refilled each day by the level control system The automated refill is controlled by a solenoid swit...

Страница 11: ...y tank on stand Optional hose from drain pump Enters top of tank to prevent siphoning 1 metre head Model 6529 2L Low Pressure Solenoid 0 70kPa mounted in enclosure 4 1 4 Underground Supply Where the w...

Страница 12: ...in the middle of the evaporation pan 5 2 Installing The Model 6529A Enclosure The stillwell enclosure is located 1 5 metres from the pan on the side away from the equator where it will not shadow the...

Страница 13: ...ment Fill the pan with water to near the reference point in the pan level gauge Check the hose connections and the pan for leaks and fix any problems Confirm that the water level in the stillwell is t...

Страница 14: ...stalled on both the float pulley and offset pulley check that the float and counterweight can rise freely from the bottom to the top of the stillwell without clashing or touching the sides 6 Rotate th...

Страница 15: ...ar powered battery system A regulator on the switch card manages battery charging All devices connect to the row of pluggable terminals located at the front of the enclosure Automatic Evaporation Syst...

Страница 16: ...lifted from the well separated in the middle and the pump lifted out for cleaning The bottom of the pump can be removed to clean and service the impeller The pump must be inverted when installed for r...

Страница 17: ...t hole of the three at the bottom of the left hand wall of the cabinet Attach the hose to the pan and seal it with a hose clamp Connect the pan end of the hose to the fitting in the top hole of the pa...

Страница 18: ...mm water level falls and the rainfall data all 0 2mm rises The data is logged in increments of 0 4mm The effects of any pan water level resets and minor water level pulsations are not recorded The tim...

Страница 19: ...following settings are recommended for a normal project You may prefer a 15 minute log interval to reduce the volume of logged data Click on the Events panel to open the listing of events Double clic...

Страница 20: ...elect Scheme from the toolbar then Save As Automatic Evaporation System OPERATING THE SITE 35 The Log Buffer Panel The Events Detail Panel You should save it with a scheme name that identifies your si...

Страница 21: ...NG THE SITE 37 6 5 Data Recovery And Review Refer to the software manual for Version 3 Software for detailed descriptions on operating the software and displaying data Select Display a Data File from...

Страница 22: ...ration and rainfall data is the accumulated total since the logger was last reset It may contain corrupting events if there has been any artificial water level changes There are two shown in the above...

Страница 23: ...ed spare parts and check instruments Take the visit file Automatic Evaporation System SITE VISITS AND MAINTENANCE 41 7 1 2 Carrying Out The Site Inspection At the site your objectives are to Recover t...

Страница 24: ...ariations Automatic Evaporation System SITE VISITS AND MAINTENANCE 43 6 Check that the derived rainfall is sensible and supported by the evaporation data 7 Select the ASCII report The file will be sav...

Страница 25: ...hould be added to the station visit file to remind the site operator to attend to the matter at the next site visit The interaction between site operation data processing reporting and review allows f...

Страница 26: ...7 3 5 Solenoid Pump Regularly check the operation of the solenoid and pump To check the condition and serviceability of the solenoid and or pump 1 Connect each device to the TEST position of the cont...