5.2.6.2.
Pressure Depth Zero Offset
Example 1: Set pressure depth offset 100mm:
Send - 01 06 00 6D 00 64 19 FC
Receive - 01 06 00 6D 00 64 19 FC
Example 2: Set pressure depth offset -10363mm:
Send - 01 06 00 6D D7 85 86 44
Receive - 01 06 00 6D D7 85 86 44
5.2.6.3.
Enable Velocity Direction
Example 1 Change (Enable negative velocity direction):
Send - 01 06 00 E2 00 01 E8 3C
Receive - 01 06 00 E2 00 01 E8 3C
Example 2 Change (Disable negative velocity direction):
Send - 01 06 00 E2 00 00 29 FC
Receive - 01 06 00 E2 00 00 29 FC
5.2.6.4.
Changing a velocity range
2 = 3345mm/s
3 = 1673mm/s (Default)
4 = 836mm/s
5 = 418mm/s
Example Change (Change Velocity Range from 1673mm/s to 3345mm/s):
Send - 01 06 00 6C 00 02 C8 16