36
Parametri
Code
Description
Set.
Min.
Max.
803
Enabled Services:
0: CH & DHW disabled
1: CH enabled
2: DHW enabled
3: CH & DHW enabled
3
0
3
322
Pump: Post-circulation
0: overrun 5 min.
1: continuous
0
0
1
787
Outdoor minimum
temp °C
10
0
30
789
Night shift °C
0: T.A.
5÷30: Value night shift
0
0/5 30
807
ACS Preheating
0
0
1
792
CH: Modulation max
100 0
100
31
CH#1 Minimum Set
point
30
20
45
39
CH#1 Max. Set point
85
50
85
650
ACS Set point Min.
35
25
45
385
ACS Set point Max.
60
50 65
48
CH#1 Set point °C
70
20
85
832
Access Code
(#)
0
0
199
To change the following parameters you must
enable the access code.
778
Burner:
0: G20 - 1 GPL
0
0
1
341
Pump: Minimum
Control
--
0
100
313
Pump: Maximum
Control
--
20 100
312
Pump: temp. diff. °C
--
5
20
775
Valvola Dev.: Stroke
time sec.
--
0
6
309
System configurations:
1: W1
2: W2
3: W3
4: W4
--
1
4
771
Sensore pressione
Acqua
0: assente - 1 presente
--
0
1
To change the parameters is required password.
Содержание S 24
Страница 1: ...E N G L I S H INSTALLATION AND SERVICING MANUAL S 24 S 28 S 35 TOUCH CONTROL Ufly BOX integrate...
Страница 10: ...10 OSA S 28 OSA S 35...
Страница 11: ...11 OSA S 24 OSA S 28 OSA S 35 View from above View from below...
Страница 41: ...41 Maintenance instructions E N G L I S H This page is intentionally left blank...
Страница 50: ......
Страница 51: ......