3.12.1 - COMBUSTION ADJUSTMENT FUNCTION ACTIVATION
After Auto Calibration GAC par. 4.3.1
Perform combustion adjustment calibration
as indicated:
If the CO2 value is not as expected, when
appears
box (+/-)
, you can retouch the value of the
Maximum Power.
If the desired value has been reached, proceed to
the next level by pressing: Ignition
If the CO2 value is not as expected, when
appears
box (+/-)
, you can retouch the value of the
Minimum Power.
If the CO2 value is not as expected, when
appears
box (+/-)
, you can retouch the value of
the Ignition. If the desired value has been reached,
proceed to the next level by pressing: Minimum
The combustion adjustment is finished.
This function allows a partial adjustment of the
CO
2
value on the following modulation points:
Maximum output
100 %
Start-up output
xx %
Minimum output
0 %