Instructions for the installer
fig. 14
3.16 - TOOLS PANEL MODULATING MASTER
COD. 37892
14 switch with indicator light
16 main fuse
18 Burner switch
19 P1 Switch pump system (cascade)
Through the general switch 14, place under tension the
framework and equipment connected to it.
The switches 18 and 19 , controlling the burner and the pump
P1 in the case of boiler cascade.
The switches 20 and 21, controls the pump Z1 (direct) and
pump Z2 (mixed).
With the temperature controller, adjusts the temperature of the
boiler, to achieve this, the thermostat will be located at the
bottom scale up. 33
The possible modulation of the burner will be managed by
thermoregulation.
On the power line control panel of the boiler, must be provided
with a switch with fuses protection
To use the instrument panel, see instruction manual for the installer.
As for the practical schemes of connection and operation, see documentation provided in the instrument panel code.
37892
20 switch system pump direct zone PZ1
21 switch system pump mixed zone Pz2
33 thermostat operation
35 Safety thermostat
The probes of the temperature controller (boiler, water heater,
external delivery) are included in the supply, environmental
probes 1 and 2 are optional, the mixing valve and its engine
command are not supplied.
If you fit the room temperature sensors (optional), temperature
environments will be determined only under the curve boiler
set by the program.
If you plan the installation of two boilers in cascade see
Section 3.19, 3.20, 3.21
.
3.17 - PROGRAMMING THE TEMPERATURE
CONTROLLER WITH SINGLE BOILER
Regarding the adjustment or programming of the temperature
controllers, see the booklet enclosed with the individual
Temperature Controller Following the parameters programmed
in the factory and therefore “can not be changed.”
Regarding the user-programmable parameters according to
your needs, see the instruction manual for the responsible of
the installation.
14
15
16
17
35
33
34
18
19
20
21
22
23
21.0
20
S
er
vi
zi
o
D
at
a/
O
ra
/V
ac
an
ze
V
is
ua
l I
nf
.
U
te
nt
e
P
ro
gr
.T
em
po
Te
cn
ic
o
Im
pi
an
to
A
cq
ua
C
al
da
C
irc
ui
to
ri
sc
. I
S
ol
ar
e/
M
F
C
irc
ui
to
ri
sc
. I
I
°C
OK
1
2
1
2
>1s
+
°C
°C
°C
BUS ID
1/2/11/Mod
Run
2
1
Содержание INOXIA GJ Series
Страница 1: ...INOXIA GJ INSTALLATION AND SERVICING MANUAL 00335290 1st edition 04 11...
Страница 21: ...21 Instructions for the installer fig 12 5 24 4 8 10 12 13 6 3 1 2 7 23 20 14 19 17 21 18 1 2 11 9 16 12 15...
Страница 54: ......
Страница 55: ......