66
FAULT
CODE
COMPONENTS CONCERNED
POSSIBLE CAUSES
CONSEQUENCES
CONDITIONS FOR EXIT
OF THE SECURITY
14
DO1
Doser, GROUP 1
disconnected, absence of signal:
- Check the sensor and the wiring
Manual dosing alarm
Automatic if fault
eliminated
15
DO1
Doser GROUP 1
short circuit:
- Check the component and the wiring
Manual dosing alarm
Automatic if fault
eliminated
16
DO1
Doser, GROUP 1
Interruption in counting for more than 5
seconds:
- Check that the doser turbine turns freely
and check the wiring (bad contact)
Manual dosing alarm
Automatic if fault
eliminated
17
DO1
Doser, GROUP 1
Infusion time more than 110 seconds,
insufficient flow:
- Check the cleanliness of the hydraulic
circuit or increase the grain size.
Infusion cycle stops
Automatic if fault
eliminated
18
EH1
DOSAMAT sensor,
GROUP 1
disconnected, absence of signal:
- Check the sensor and the wiring
Manual start alarm
Automatic if fault
eliminated
19
EH1
DOSAMAT sensor,
GROUP 1
short circuit:
- Check the component and the wiring
Manual start alarm
Automatic if fault
eliminated
20
TS2
Safety thermostat on
GROUP 2
triggered following overheating
- Check the regulation circuit SR2 and the
thermostat TS2 (manual reset)
Heating stopped on Group
2 - Control box BG2 on
stand-by
Fault eliminated and
manual reset of TS2 and
machine reset
21
SR2
Thermostat sensor,
GROUP 2
disconnected, absence of signal:
- Check the sensor and the wiring
Heating stopped on Group
2 - Control box BG2 on
stand-by
Fault eliminated and
machine reset performed
22
SR2
Thermostat sensor,
GROUP 2
short circuit:
- Check the sensor and the wiring
Heating stopped on Group
2 - Control box BG2 on
stand-by
Fault eliminated and
machine reset performed
23
SR2
Thermostat sensor,
GROUP 2
Reading outside the authorised range:
- Check the programmed value and the
sensor.
Heating stopped on Group
2 - Control box BG2 on
stand-by
Automatic if fault
eliminated
24
DO2
Doser, GROUP 2
disconnected, absence of signal:
- Check the sensor and the wiring
Manual dosing alarm
Automatic if fault
eliminated
25
DO2
Doser, GROUP 2
short circuit:
- Check the component and the wiring
Manual dosing alarm
Automatic if fault
eliminated
26
DO2
Doser, GROUP 2
Interruption in counting for more than 5
seconds:
- Check that the Doser, turbine turns freely
and check the wiring (bad contact)
Dosage alarm or manual
stop
Automatic if fault
eliminated
27
DO2
Doser, GROUP 2
Infusion time more than 110 seconds,
insufficient flow:
- Check the cleanliness of the hydraulic
circuit or increase the grain size.
Infusion cycle stops
Automatic if fault
eliminated
28
EH2
DOSAMAT sensor,
GROUP 2
disconnected, absence of signal:
- Check the sensor and the wiring
Manual start alarm
Automatic if fault
eliminated
29
EH2
DOSAMAT sensor,
GROUP 2
short circuit:- Check the component and the
wiring
Manual start alarm
Automatic if fault
eliminated
30
TS3
Safety thermostat on
GROUP 3
triggered following overheating
- Check the regulation circuit SR3 and the
thermostat TS3 (manual reset)
Heating stopped Group 3
box BG3 on stand-by
Fault eliminated and
manual reset of TS3 and
machine reset
31
SR3
Thermostat sensor,
GROUP 3
disconnected, absence of signal:
- Check the sensor and the wiring
Heating stopped Group 3
box BG3 on stand-by
Fault eliminated and
machine reset performed
32
SR3
Thermostat sensor,
GROUP 3
short circuit:
- Check the sensor and the wiring
Heating stopped Group 3
box BG3 on stand-by
Fault eliminated and
machine reset performed
Содержание Stella di Caffe
Страница 1: ...NZ9009 02 15 ...
Страница 49: ...49 Diagrams BGX control box connections ...
Страница 50: ...50 BTA BST control box connections ...
Страница 51: ...51 CPU board connections Reserved for information connections ...
Страница 53: ...53 ...
Страница 55: ...55 ...
Страница 57: ...57 Wiring diagrams ...
Страница 58: ...58 ...
Страница 59: ...59 ...
Страница 77: ...77 ...
Страница 78: ...78 WITH INTERFACE JP8 12V CN13 CPU Pt no 45360 ...
Страница 79: ...79 WITHOUT INTERFACE CPU Pt no 45360 JP8 12V CN13 ...
Страница 84: ...84 The dotted lines represent the main menu 11 STELLA PROGRAMME FLOWCHART Level 0 User ...
Страница 85: ...85 The dotted lines represent the main menu Level 1 Coffee specialist Direct Access ...
Страница 86: ...86 If installed in the machine Level 2 Barista The dotted lines represent the main menu Direct Access ...
Страница 87: ...87 The dotted lines represent the main menu Level 3 Manager Boss Direct Access ...
Страница 88: ...88 The dotted lines represent the main menu Level 4 Technician USB dongle level Direct Access ...
Страница 90: ...90 ...
Страница 94: ...94 ...