Update procedures
During an update you should:
-
If possible save the machine settings on the
machine USB dongle
(Maintenance
data transfer
settings export
-
Perform an update of the CPU with a
USB+ dongle
-
Import the CIM configuration from
the machine USB dongle
(Maintenance
data transfer
CIM
import ) or reconfigure the machine using CIM creator
- Import the machine configuration (Maintenance
data transfer
settings import)
BTA update
-
Start the machine and wait for the end of the BTA starting cycle
-
At the end of the starting cycle insert the
USB + dongle
-
The hourglass pointer appears, followed by the update screen
-
Uncheck "
Calib
" to stop the countdown and then check "
BTA
" and press "
upgrade
"
If you do not uncheck "
Calib
", the calibration procedure starts at the end of the countdown.
See BTA calibration procedure
-
Confirm "
upgrade
"
-
The control box will restart automatically. The progress of the update is not visible.
-
Note: During an update the restarting of the control box takes longer, DON'T SWITCH THE
MACHINE OFF
-
Wait for the end of the starting cycle
-
When the screen background reappears, the BTA is updated with the time and date.
CPU update
If you have not exported the CIM and the settings, they will be lost and will need to be
reconfigured.
-
Proceed in the same way as for the BTA
-
check "
CPU
" and press
“upgrade
"
Содержание Stella di Caffe
Страница 1: ...NZ9009 02 15 ...
Страница 49: ...49 Diagrams BGX control box connections ...
Страница 50: ...50 BTA BST control box connections ...
Страница 51: ...51 CPU board connections Reserved for information connections ...
Страница 53: ...53 ...
Страница 55: ...55 ...
Страница 57: ...57 Wiring diagrams ...
Страница 58: ...58 ...
Страница 59: ...59 ...
Страница 77: ...77 ...
Страница 78: ...78 WITH INTERFACE JP8 12V CN13 CPU Pt no 45360 ...
Страница 79: ...79 WITHOUT INTERFACE CPU Pt no 45360 JP8 12V CN13 ...
Страница 84: ...84 The dotted lines represent the main menu 11 STELLA PROGRAMME FLOWCHART Level 0 User ...
Страница 85: ...85 The dotted lines represent the main menu Level 1 Coffee specialist Direct Access ...
Страница 86: ...86 If installed in the machine Level 2 Barista The dotted lines represent the main menu Direct Access ...
Страница 87: ...87 The dotted lines represent the main menu Level 3 Manager Boss Direct Access ...
Страница 88: ...88 The dotted lines represent the main menu Level 4 Technician USB dongle level Direct Access ...
Страница 90: ...90 ...
Страница 94: ...94 ...