68
FAULT
CODE
COMPONENTS CONCERNED
POSSIBLE CAUSES
CONSEQUENCES
CONDITIONS FOR EXIT
OF THE SECURITY
48
EH4
DOSAMAT sensor,
GROUP 4
disconnected, absence of signal:
- Check the sensor and the wiring
Manual start alarm
Automatic if fault
eliminated
49
EH4
DOSAMAT sensor,
GROUP 4
short circuit:
- Check the component and the wiring
Manual start alarm
Automatic if fault
eliminated
50
DOE
Doser, HOT WATER
disconnected, absence of signal:
- Check the sensor and the wiring
Manual dosing alarm
Automatic if fault
eliminated
51
DOE
Doser, HOT WATER
short circuit:
- Check the component and the wiring
Manual dosing alarm
Automatic if fault
eliminated
52
DOE
Doser, HOT WATER
Interruption in counting for more than 5
seconds:
- Check that the doser turbine turns freely
and check the wiring (bad contact)
Dosage alarm or manual
stop
Automatic if fault
eliminated
53
DOE
Doser, HOT WATER
Cycle time longer than 110 seconds,
insufficient flow:
- Check the cleanliness of the hydraulic
circuit
Cycle stop : EVE
Automatic if fault
eliminated
54
STS
SteamAir sensor
disconnected, ABSENCE of supply of signal:
- Check the sensor and the wiring
Alarm, Manual stop
Automatic if fault
eliminated
55
STS
SteamAir sensor
short circuit:
- Check the sensor and the wiring
Alarm, Manual stop
Automatic if fault
eliminated
56
STS
SteamAir sensor
Reading outside the authorised range:
- Check the programmed value and the
sensor.
Alarm, Manual stop
Automatic if fault
eliminated
57
CP1
Pressure sensor,
GROUP 1
disconnected, absence of signal:
- Check the sensor and the wiring
Alarm
Automatic if fault
eliminated
58
CP1
Pressure sensor,
GROUP 1
short circuit:
- Check the sensor and the wiring
Alarm
Automatic if fault
eliminated
59
CP1
Pressure sensor,
GROUP 1
Reading outside the authorised range:
- Check the programmed value and the
sensor.
Alarm - Sensor reading
not accepted - Pressure
set point replaced by timer
(see coffee cycle with pre-
infusion)
Automatic if fault
eliminated
60
CP2
Pressure sensor,
GROUP 2
disconnected, absence of signal:
- Check the sensor and the wiring
Alarm
Automatic if fault
eliminated
61
CP2
Pressure sensor,
GROUP 2
short circuit:
- Check the sensor and the wiring
Alarm
Automatic if fault
eliminated
62
CP2
Pressure sensor,
GROUP 2
Reading outside the authorised range:
- Check the programmed value and the
sensor.
Alarm - Sensor reading
not accepted - Pressure
set point replaced by timer
(see coffee cycle with pre-
infusion)
Automatic if fault
eliminated
63
CP3
Pressure sensor,
GROUP 3
disconnected, absence of signal:
- Check the sensor and the wiring
Alarm
Automatic if fault
eliminated
64
CP3
Pressure sensor,
GROUP 3
short circuit:
- Check the sensor and the wiring
Alarm
Automatic if fault
eliminated
Содержание Stella di Caffe
Страница 1: ...NZ9009 02 15 ...
Страница 49: ...49 Diagrams BGX control box connections ...
Страница 50: ...50 BTA BST control box connections ...
Страница 51: ...51 CPU board connections Reserved for information connections ...
Страница 53: ...53 ...
Страница 55: ...55 ...
Страница 57: ...57 Wiring diagrams ...
Страница 58: ...58 ...
Страница 59: ...59 ...
Страница 77: ...77 ...
Страница 78: ...78 WITH INTERFACE JP8 12V CN13 CPU Pt no 45360 ...
Страница 79: ...79 WITHOUT INTERFACE CPU Pt no 45360 JP8 12V CN13 ...
Страница 84: ...84 The dotted lines represent the main menu 11 STELLA PROGRAMME FLOWCHART Level 0 User ...
Страница 85: ...85 The dotted lines represent the main menu Level 1 Coffee specialist Direct Access ...
Страница 86: ...86 If installed in the machine Level 2 Barista The dotted lines represent the main menu Direct Access ...
Страница 87: ...87 The dotted lines represent the main menu Level 3 Manager Boss Direct Access ...
Страница 88: ...88 The dotted lines represent the main menu Level 4 Technician USB dongle level Direct Access ...
Страница 90: ...90 ...
Страница 94: ...94 ...