Programming Manual UDP3000S Series
Instruments.uni-trend.com
38
/
49
Function
:
Set the output signal polarity for output trigger.
Description
:
D0|D1|D2|D3
:
Select trigger IO
,
D0-IO1
,
D1-IO2
,
D2-IO3
,
D3-IO4.
POSItive
:
Output the positive signal
NEGAtive
:
Output the negative signal
For Example
:
:TRIGger:OUT:POLArity D0, POSItive Set the output signal of IO1 to positive.
:TRIGger:OUT:POLArity?
Format
:
:TRIGger:OUT:POLArity? {D0|D1|D2|D3}
Function
:
Query the output signal polarity of output trigger
Description
:
D0|D1|D2|D3
:
Select trigger IO
,
D0-IO1
,
D1-IO2
,
D2-IO3
,
D3-IO4.
Return
:
“{POSITIVE|NEGATIVE}”.
POSITIVE
:
Output the positive signal
NEGAtive
:
Output the negative signal
For Example
:
:TRIGger:OUT:POLArity? D0
Query the output signal polarity of IO1.
Return
:
POSITIVE
Return result
:
The output signal polarity of IO1 is positive.
11. PRESet
:PRESet#[:APPLy]
Format
:
:PRESet#[:APPLy]
Function
:
Apply the preset parameter of the specified group to the output setting parameter.
Description
:
The optional values for # are“1|2|3|4|5”, cannot be omitted and the corresponding preset group.
For Example
:
:PRESet1:APPLy
:PRESet#:SET:VOLTage
Format
:
:PRESet#:SET:VOLTage {CH1|CH2|CH3|SER|PARA}, {<volt>|MINimum|MAXimum}
Function
:
Set the voltage value for the preset group.
Description
:
The optional values for # are“1|2|3|4|5”, cannot be omitted and the corresponding preset group.
For Example
:
:PRESet1:SET:VOLTage CH1, 5.00
:PRESet#:SET:VOLTage?
Format
:
:PRESet#:SET:VOLTage? {CH1|CH2|CH3|SER|PARA}
Function
:
Query the voltage value of the preset group.
Description
:
The optional values for # are“1|2|3|4|5”, cannot be omitted and the corresponding preset group. It
returns the real value of voltage.
For Example
:
:PRESet1:SET:VOLTage? CH1
Return
:
05.00
:PRESet#:SET:CURRent
Format
: