Programming Manual UDP3000S Series
Instruments.uni-trend.com
24
/
49
:LISTout:TEMPlet:INVErt
Format
:
:LISTout:TEMPlet:INVErt {0|1|OFF|ON}
Function
:
Set the phase invert switch of the template for the list output mode of the current channel.
Description
:
Only the template of sine wave, pulse and rampe have phase invert function. The command can
only be used in these template.
For Example
:
:LISTout:TEMPlet:INVErt ON
:LISTout:TEMPlet:INVErt?
Format
:
:LISTout:TEMPlet:INVErt?
Function
:
Query the phase invert switch of the template for the list output mode of the current channel.
Description
:
It returns {OFF|ON }.
For Example
:
:LISTout:TEMPlet:INVErt?
Return
:
ON
:LISTout:TEMPlet:WIDTh
Format
:
:LISTout:TEMPlet:WIDTh <value>
Function
:
Set the pulse width of the pulse width template for the list output mode of the current channel.
Description
:
value
:
floating-number value
,
the unit is second. To specifies pulse width, range
:
0.1—
(
period-
0.1
)
. The command can only be used in pulse width template.
For Example
:
:LISTout:TEMPlet:WIDTh 5.0
:LISTout:TEMPlet:WIDTh?
Format
:
:LISTout:TEMPlet:WIDTh?
Function
:
Query the pulse width of the pulse width template for the list output mode of the current channel.
Description
:
It returns <value>
,
floating-number value
,
the unit is second.
For Example
:
:LISTout:TEMPlet:WIDTh?
Return
:
5.0
:LISTout:TEMPlet:PERIod
Format
:
:LISTout:TEMPlet:PERIod <value>
Function
:
Set the period of the pulse width template for the list output mode of the current channel.
Description
:
value
:
floating-number value
,
the unit is second. To specifies the period of pulse, range
:
(
pulse width + 0.1
)
——9999.9. The command can only be used in pulse width template.
For Example
:
:LISTout:TEMPlet:PERIod 10.
:LISTout:TEMPlet:PERIod?
Format
:
:LISTout:TEMPlet:PERIod?
Function
:
Query the period of the pulse width template for the list output mode of the current channel.
Description
:
It returns <value>
,
floating-number value
,
the unit is second.