INSTALLATION AND OPERATION MANUAL
phase, on the display will appear “Igni-
tion” (“PA1”). The pellet starts falling in
the burner and in few minutes the flame
appears. Once the flame is present, the di-
splay shows “PB”, “Stabilization” and then
“Normal”.
5.4 Operating characteristics
The priority of operation of the stove is the
room temperature. If the fan power is set
“Auto, the fan will be autoamtically syncro-
nised with the actual combustion power.
If the combustion power is set “Auto”, the
flame is automatically regulated according
to the temperature in the room of installa-
tion read by the temperature probe. If in
the menu “Power” is set “1”, the relative
operational consequences are valid pro-
portionally for any other power level set
manually.
It is recommended to set “Auto” in
the menu “Power” and to regulate
the temperature only in menu “Ther-
mostats”. A wrong manual setting,
for example, low value of the fan in
the menu Remote Room and high
power in the menu Combustion with
unsatisfied thermostats, can cau-
se alarm related to the high smoke
temperature.
Operation characteristics
Menu
Power
Combustion
Auto
Auto
Auto
1
1
6
6
Canalisation
Auto
Auto
Auto
Auto
6
Auto
6
Menu
Thermo-
stats
Room
thermostat*
> Room T°
< Room T°
> Room T°
> Room T°
> Room T°
< Room T°
> Room T°
Remote room
thermostat**
> Remote
room T°
> Remote
room T°
< Remote
room T°
> Remote
room T°
> Remote
room T°
> Remote
room T°
< Remote
room T°
Operation
Max combu-
stion, max
fans power
Combustion
at minimum,
fans at mini-
mum
Max combu-
stion, max
room fan,
ducted fan at
minimum
Max combu-
stion, fans at
minimum
Combustion
at minimum,
room fan at
minimum,
ducted fan at
power 6
Combustion
at minimum,
room fan at
minimum,
ducted fan at
power 6
Combustion at
power 6, room
fan at power
6, ducted fan
at minimum
(*) “Heating” and “Room” referred to the room of installation. The fan is commanded by the temperature probe placed close to the
stove.
(**) “Canalisation” and “Remote Room” referred to the room with ducted air heating. The fan is commanded by the probe placed in
the room with ducted heating.
5.5 Turn Off
To turn the stove off, press and hold for
some seconds the button ON/OFF. The
auger will stop feeding pellets. The air fan
remain ON until the combustion gas tem-
perature drops below the setpoint. When
the stove stops, on the display will appear
Do not disconnect power supply until
the stove is completely cooled down.