12
caldoungaro.it
Service
Loading
the menu is for autimatic pellet loading. It will stops automatically after 300 seconds. The thermostove
must be OFF when this option must be enabled. After the loading has stopped, clean the burn pot with ash
vacuum cleaner before starting the ignition.
Test Loading
This menu is for the exclusive access of Ungaro Technical Support
Display
List nodes
This menu is for the exclusive access of Ungaro Technical Support
Contrasto
menu to adjust screen contrast
Min. light
menu to adjust screen brightness
Sound
in this menu is possible to turn on or off the keyboard sound
System
menu
This menu is for the exclusive access of Ungaro Technical Support
5. Operation
5.1 Before ignition
Before turning on the generator the first
time, or any other time, check if:
• The power supply cable is connected to
the wall socket ant to the heat generator.
The main switch of the stove must be in
the “ON” position. The display must be lit;
• Make sure that on the display appears the
message “OFF”. Should there be an alarm
code, solve its cause and reset the alarm
as described in the chapter “Alarms”;
• The pellet hopper is full;
• The combustion chamber is clean;
• There is no foreigh body or unburnt pellet
in the burn pot;
• There is no unburnt pellet in the ash are
perfectly in place and the butterfly screws
are adequately tightened;
• The tecnical door and the aesthetical door
are closed.
5.2 Settings
Press the button “SET” to access to the pro-
grammation menu.
• In the menu “Power”, submenu “Canali-
saton”, set “Auto” if you wish to propor-
tionate the speed of the upper fan to the
combustion power. If you prefer to control
the fan manually, set the desired speed
value choosing from 1 to 6 (maximum).
In menu “Thermostats”, submenu “Room”
set the desired temperature in the room
of installation.
• If the stove has ductable heating, the
temperature in the remote room must be
set in the submenu “Remote room” , it will
be detected with the probe placed in the
room with ducted hot air. Press and hold
the button “Set” to access to the comple-
mentary programming.
• In the menu “Service”, submenu “Auto-
matic Power”, set “ON” (recommended
setting) to to proportionate the combu-
stion power to the value set in the menu
“Room Thermostat” and the actual tem-
perature relieved by the room probe. If
the submenu “Automatic Power” is set
“OFF”, in the menu “Power” will be seen
the submenu “Combustion” , where can
be set the power of combustion of the ge-
nerator. For any configuration the speed
of the fan is always proportionated to the
combustion power.
5.3 Ignition
Press and hold the power botton until the
signal “Check Up” appears on the display.
In this phase the stove carries out auto-
matic cleaning, components and security
test and draft checking. Completed the test