Instructions Manual
-
Multiple Roots Type Dry Pump GR60/90/180
YK09-0023-DI-003-02
viii
Nitrogen Gas Piping <Removal>
(1) Before removal of the nitrogen gas pipes, close the feed valve of
nitrogen gas.
(2) The pipe on the device side has residual pressure. Install a pressure
gauge in the nitrogen supply source of the device (on the way to the
pump in the pipe) and check that the pressure decreases down to the
atmospheric pressure, before removing the nitrogen gas pipes. If the
inner pressure is high during the work, there is a risk that the pipes
may be disconnected with force and you may get injured.
Intake and exhaust piping <Removal>
(1)
Remove
according to the installation manual of the device.
(2)
For
a while after the operation stops, do not touch the intake and
exhaust pipes since they are subjected to high temperature.
Remove after the pump temperature becomes low.
(3)
Fully
seal the intake and exhaust ports using shutoff flanges etc.
Transportation
(1) This product has casters. But do not transport it on casters over a
long distance.
(2) The mass of each product is as follows:
GR60: 128kg
GR90: 188kg
GR180: 268kg
A load over the safety standard value is required for transportation,
and therefore you may strain your back. Transport it by hanging with
cargo handling equipment (such as a mobile crane), or put and fix it
on a pallet and transport it on a pallet track.
(3) This product uses vinyl tubes as nitrogen gas and cooling water
pipes. Transport the product with care not to have it in contact with
posts and walls.
WARNING
WARNING
WARNING
Содержание GR60
Страница 2: ......
Страница 12: ...Instructions Manual Multiple Roots Type Dry Pump GR60 90 180 YK09 0023 DI 003 02 x GR60 GR90 GR180...
Страница 27: ...Instructions Manual Multiple Roots Type Dry Pump GR60 90 180 YK09 0023 DI 003 02 9 GR90...
Страница 28: ...Instructions Manual Multiple Roots Type Dry Pump GR60 90 180 YK09 0023 DI 003 02 10 GR180...