background image

www.ultratecfx.com 

31

12. Return to the controller.  Place the SAFE/ARMED key in the ARMED position.  At this point you can 

fire some or all of your cues as a test.  The Red channel LEDs of the modules should flash briefly 

when the modules are fired.  This test confirms communications and shows the operator which 

channels on which modules are firing without the use of test matches.

13. Turn the SAFE/ARMED key to the SAFE position.  Turn the SLAVE POWER key to the ‘OFF’ position.  

Firing current is now disconnected from the slave modules and all 16 Red channel LEDs on all 

modules should be lit.

14. Slave modules can be turned ‘OFF’ using the key on the front panel.
15. You are now ready to connect pyro devices to the system.

16. Once pyro is connected you must restart the modules.  Sound an all clear and be certain that all 

personnel and property are clear of pyro areas.

17. Turn the slave modules ‘On’ using the key on the front panel.  All 16 Red channel LEDs should be 

lit.

18. Return to the console.  While maintaining the all clear, turn the SLAVE POWER key to the ON posi-

tion.  The SAFE/ARMED key must remain in the SAFE position.  You are now ready to test for match 

continuity.  Turn the encoder (and use the port select if you have the multi-port option) to ensure 

that matches are present on their proper channels.  Investigate missing matches if any.

Wiring Chart

Содержание SureFire

Страница 1: ...SureFire Pyrologic Digital Controller Operations Manual www ultratecfx com VER 11 07 10...

Страница 2: ...r Front Panel Page 10 Surefire Pyrologic Controller Rear Panel Page 11 Channel Select Buttons Encoder Page 27 Surefire Digital 16 Channel Slave Module Page 28 Surefire Digital Airburst Slave Module Pa...

Страница 3: ...ox A restocking charge of up to 25 may be levied Only credits are issued to the dealers account Any product not returned within 30 days is considered purchased Warning Ultratec Special Effects Inc con...

Страница 4: ...t a suitable first aid kit is available and that personnel are trained in its use 5 There must be no smoking exposed flames or any other sources of ignition in the vicinity of pyro technic material at...

Страница 5: ...erform identically this must be considered when locating devices 14 Ultratec Pyrotechnics must only be used in conjunction with Ultratec Firing Systems or Ultratec approved devices No liability of any...

Страница 6: ...yrologic Programmable Controller Type Micro Processor Controlled Low Voltage Firing System Weight 17 Lbs Power Rating 110 Volt A C 50 60 Hz 0 75 Amps 240 Volt A C 50 60 Hz 0 35 Amps Technical Specific...

Страница 7: ...rol The channel select buttons also have a Green LED This LED indicates the presence of continuity on the corresponding channel of the slave as indicated by the Remote Slave Display The Remote Slave D...

Страница 8: ...e Slave Power is OFF Slave Power On is indicated by the Green LED On in the Status Indicator section When Slave Power is ON the firing current is available to the slave channel outputs Fault Indicator...

Страница 9: ...Power Off The slave power is required to run the diagnostic routine therefore when the SLAVE POWER key switch is OFF the system will indicate a FAULT Note that when the SLAVE POWER is OFF all 16 faul...

Страница 10: ...and for limited functions during Run time A Keypad layout and brief description of their functions follows In the instruction section key presses are indicated with angle brackets Data Link When the d...

Страница 11: ...selection or Groups of Channels stages will be fol lowed by a Delay Time DELAY Calls the Delay Time select screen where the time value of the symbol is determined Chase speed VIEW Flashes the bottom...

Страница 12: ...cted slave module is On Line If the operator expects to see matches on the selected slave and none appear the slave is not ON Line or the SAFE ARMED key is not in SAFE position In ARMED mode match and...

Страница 13: ...16 This system of the first digit representing the slave module address and the second 2 digits repre senting the channel on that slave continues up to the Encoder limit of 9 Each 16 channel slave add...

Страница 14: ...e Asterisk that highlights the current selection To chose the highlighted function press START Capitalized words surrounded by the refer to keys on the keypad Programming Operator Shows To program an...

Страница 15: ...select a channel for a Group Fire turn the numerical encoder 1 to 9 and press a channel but ton The matching Numerical channel number is displayed on the LCD followed by end 2 To accept the channel as...

Страница 16: ...ed at once ALL channels preceding the first symbol The program then pauses for the Delay time Delay time is selected during programming The next Stage of the Chase is Fired after the pause The sequenc...

Страница 17: ...reen press VIEW again To accept the displayed Delay time press DELAYMS key The Delay time is now inserted at ALL symbol locations 1__108 609 114 316 109 101 102 501 116 403 911E The above cue will fir...

Страница 18: ...RUN OPERATOR X MEMORY SHOW ARE YOU SURE PRESS DELETE TO CANCEL PRESS ENTER TO CONFIRM Editing a programmed memory location can be done at the Program Operator Show Menu by high lighting the memory lo...

Страница 19: ...se The Chase sequence will continue ONLY if the FIRE button is held down Release of the FIRE button during a Chase will halt the Cue Re pressing the FIRE button will begin where the Chase halted To sk...

Страница 20: ...Link switch must be off not illuminated When the Pyro Logic Controller is powered on the operator will see the Start up screen Start Up Screen SureFire Pyro Contoller Press Start key to begin VX XX Wh...

Страница 21: ...ugh TC 4 to be programmed ENTER starts edit program mode In an empty memory location the screen looks like 1 end End of Show Channel Selection for a Group Fire MIDI Cue A Group Fire is defined as a cu...

Страница 22: ...t follows Note that channel selections can be duplicated in the same Cue The program will assemble the channel list properly during storage If channel selections are repeated in subsequent Cues the co...

Страница 23: ...in Menu select RUN TIME CODE SHOW Press START This prompt appears RUN A PREVIOUSLY PROGRAMMED SHOW BY RECALLING ANY OF THE OP PROGRAMS Select the programmed memory keys to be loaded by selecting a key...

Страница 24: ...s Cues can be loaded and fired in any order out of sequence by sending the corresponding MIDI Note On command MIDI Notes must include a velocity of Hex 7F MIDI note On 127 second highest plus the corr...

Страница 25: ...0 91 7E 7F fire cue 9 91 7E 7F fire cue 80 91 7E 7F fire cue 10 91 2C 7F load cue 45 91 7E 7F fire cue 11 91 7E 7F fire cue 45 Octave 2 1 0 1 2 3 4 5 6 7 8 Data Dec hex Dec hex Dec hex Dec hex Dec hex...

Страница 26: ...The cues will be displayed One cue per line on all 4 lines VERY IMPORTANT The controller will FIRE the CUE displayed on the TOP LINE of the LCD screen The FIRE button will be LIVE if all the safety fe...

Страница 27: ...The operator releases the Positive Enable after Cue 2 has been uploaded to the remotes When the FIRE command is received MIDI note on 127 Cue 2 will NOT Fire 10 seconds later the controller receives M...

Страница 28: ...can occur with 5 frames between events If SMPTE time code is used as the source and the rate of the SMPTE code is 24 frames per second one frame is equal to 41 milliseconds It will be necessary to upl...

Страница 29: ...ave ad dress and does NOT correspond to 0 on the controller display The slave must be powered Off then On for the encoder change to be in effect power On Off key The slave address corresponds to the S...

Страница 30: ...ey can be removed in the Off position for safety 48 Channel Slave Modules have encoders mounted on the back panel The encoders should be set to occupy 3 consecutive numbers ie 123 or 234 etc Status Mo...

Страница 31: ...address is invalid The 16 channel slave Encoder Channel num ber tables are the same as the channel select numbers on the controller For Example A 16 channel slave with the Encoder set to address 5 co...

Страница 32: ...t the operation of the slave modules over the long term 3 In the case of concussion effects place the modules at least 15 feet from the concussion pots The shock from the concussions can damage the el...

Страница 33: ...should be lit 14 Slave modules can be turned OFF using the key on the front panel 15 You are now ready to connect pyro devices to the system 16 Once pyro is connected you must restart the modules Soun...

Отзывы: