background image

 

 

UCH0053/UCH0054 Operation Manual 

Newark, New York | Phone: 315-332-7100 | Fax: 315-331-7800 

©2017 Ultralife Corporation • www.ultralifecorp.com • All specific subjects to change without notice 

The information contained herein is for reference only and does not constitute a warrant of performance • 08 SEP 17 UBI-05346 REV: - 

Page 15 of 21 

3.6 

USB Charging Port 

The UCH0054 charger has two USB ports and UCH0053 charger has six USB ports provided on the charger 

which will deliver 5V/500mA power. A standard A-type USB cable can be used. 

3.7 

AC & DC Circuit Breakers 

The  UCH0053/UCH0054  chargers  are  equipped with manual resettable circuit breakers. These  devices 

protect the charger from overload conditions. The circuit breaker will open at the time of over load or short 

circuit in the unit and power to the charger will be interrupted. The circuit breaker is reset by pressing the 

center button. 

3.8 

Battery Calibration 

The UCH0053/UCH0054 chargers allow for calibration of the internal fuel gauge of smart batteries. In order 

to enable calibration, the user must manually press the calibration button, labeled “CAL ENABLE” below the 
LED indicators. Pressing the calibration switch will begin the calibration routine for any and all batteries 
connected to the charger that are requesting calibration at the time of the switch activation. If no batteries 
are requesting calibration, pressing the calibration switch will force the calibration routine on all non-smart 
batteries connected to the charger.  A calibration cycle consists of a complete charge, followed by a 
complete discharge, and finished with a complete charge.  The battery calibration cycle may take up to 
24hrs to complete. During the discharge portion, all 3 status LED’s will be illuminated. 

 

3.9 

Start-up & Connection Sequence 

The user can either plug the UCH0053/UCH0054 chargers into a power source or attach the batteries to the 
unit first. Once the batteries are attached and power applied to the unit, the batteries automatically start 
charging, regardless of the order of operations. 

 

3.10 

LED Indicators 

There are four groups of LEDs indicating the status of the charger. Refer to the following section for a 
description of the operation of the LEDs. 
 

3.10.1 

 "Battery Detection & Charging" Indicator LEDs  

 

When a battery is inserted into the UCH0053/UCH0054 chargers, amber LEDs labeled "CHARGE 1A, 1B, 2A, 
2B" will start flashing which will indicate that batteries are detected in the corresponding location in the 
bays. If the battery type is authorized by the charger, charging will commence, and the LEDs will change 
from flashing to steady. If the battery type is not authorized by the charger or a fault is detected, the amber 
LEDs will cease flashing and the RED LEDs will illuminate, indicating the failure/fault notification. 

 

 

Содержание UCH0053

Страница 1: ...NY 14513 USA Telephone 315 332 7100 FAX 315 331 7800 E MAIL sales ulbi com Website www ultralifecorporation com Copyright 2017 Ultralife Corporation All Rights Reserved Disclaimer of Liability Inform...

Страница 2: ...of Liability 1 1 ABOUT THIS MANUAL 1 1 Symbols Used 5 1 2 General Safety Instructions 6 2 PRODUCTDESCRIPTION 2 1 Charge Safety 7 2 2 xx90 Battery Detection 7 2 3 Charger Operational Temperature 8 2 4...

Страница 3: ...1 AC Input Circuit Breaker 10 13 Internal Battery Bay 4 HH Interface 10 2 DC Input Circuit Breaker 10 14 Internal Battery Bay 5 HH Interface 10 3 AC Inlet 10 15 Internal Battery Bay 6 HH Interface 10...

Страница 4: ...re unavailable for use on some selected versions of the UCH0053 UCH0054 chargers 14 3 5 Charging via Adapters 14 3 6 USB Charging Port 15 3 7 AC DC Circuit Breakers 15 3 8 Battery Calibration 15 3 9 S...

Страница 5: ...ese safety WARNINGS and CAUTIONS must be followed at all times WARNING Warning statements mean danger They identify practices procedures or conditions such as high voltage that could result in injury...

Страница 6: ...e unit to wet conditions rain or snow with the lid open Use of an attachment not recommended or sold by Ultralife Corporation may result in risk of fire damage to the charger electric shock or persona...

Страница 7: ...d caution instructions located in section 1 to prevent the mischarge or catastrophic destruction of a battery While inherently safe misuse of the UCH0053 UCH0054 charger may result in damage to the ba...

Страница 8: ...individual bay charging modules The UCH0053 charger has six external charging ports whereas the UCH0054 charger has two external charging ports Alternate approved batteries that are unable to be inser...

Страница 9: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 Figure 1 UCH0054 Charger Top View 1 AC Input Circuit Breaker 9 Adapter Cable Storage Pocket 2 AC Inlet 10 Fan Outlet 3 DC Input Circuit Breaker 11 Internal Battery B...

Страница 10: ...ttery Bay 5 HH Interface 3 AC Inlet 15 Internal Battery Bay 6 HH Interface 4 DC Input Banana Jacks 16 Internal Battery Bay 1 xx90 Interface 5 Technician Ports 17 Internal Battery Bay 2 xx90 Interface...

Страница 11: ...ately sized WARNING Never alter the AC cord or plug provided Improper connection can result in a risk of an electrical shock Ultralife Corporation recommends a minimum of 16 AWG wire be used for the A...

Страница 12: ...X batteries are inserted the UCH0054 charger is able to charge four batteries at one time whereas UCH0053 charger will charge twelve batteries at one time The battery type is automatically detected wh...

Страница 13: ...completely recharge the batteries listed in the chart below Battery Description Approximate Charge Time UBI 2590 Lithium Ion Li ION 12 24 VDC 3 to 5 hours BB 2590 U Lithium Ion Li ION 12 24 VDC 3 to 5...

Страница 14: ...arge is complete on a set of batteries the charger will automatically switch to the next set of batteries requesting charge It is not recommended to charge batteries that are not listed in the table a...

Страница 15: ...at the time of the switch activation If no batteries are requesting calibration pressing the calibration switch will force the calibration routine on all non smart batteries connected to the charger...

Страница 16: ...Greater than 65 C Battery is not properly inserted Charger is unable to charge the battery Internal charger temperature is too high 3 10 4 Calibration Request Indicator LEDs The amber LED labeled CAL...

Страница 17: ...and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 17 of 21 3 10 6 AC DC Supply Indicator LEDs The AC and DC supply LEDs indicate the active power source for the UCH0053 UC...

Страница 18: ...tion dampened non abrasive cloth With power removed rinse with a water dampened non abrasive cloth and allow to air dry or wipe dry with a clean dry non abrasive cloth Be sure all areas are dry before...

Страница 19: ...ompleted Steady Red Fault Failure Flashing Calibration LED Amber Calibration request Steady Calibration LED Amber Calibration started Table 3 Electrical Characteristics Parameter Value DCIN Operating...

Страница 20: ...d herein is for reference only and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 20 of 21 6 1 Contact Return Information Please call 315 332 7100 to obtain an RMA number pr...

Страница 21: ...com All specific subjects to change without notice The information contained herein is for reference only and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 21 of 21 Revisi...

Отзывы: