background image

 

 

UCH0053/UCH0054 Operation Manual 

Newark, New York | Phone: 315-332-7100 | Fax: 315-331-7800 

©2017 Ultralife Corporation • www.ultralifecorp.com • All specific subjects to change without notice 

The information contained herein is for reference only and does not constitute a warrant of performance • 08 SEP 17 UBI-05346 REV: - 

Page 8 of 21 

 

2.3 

Charger Operational Temperature 

The charger is designed to operate between a temperature range of -30°C to 55°C.  If the charger is outside 
the normal operating temperature, the red fault LED’s will illuminate solid and charging is stopped.  Normal 
operation will resume when the charger returns to within the operating temperature range.  If a smart 
battery is outside its allowable charge temperature range, the charger will flash the red fault LED’s and not 
initiate a charge. 

 

2.4 

USB Charging Port 

The UCH0053/UCH0054 charger has USB Type A charging ports which will provide constant DC 5V/0.5A. 

The UCH0053 charger has six USB Type A charging ports whereas the UCH0054 charger has two USB Type 

A charging ports. These USB ports can only be used for the purpose of charging.  

 

2.5 

External Charging Ports 

The UCH0053/UCH0054 charger has external charging ports which work in sequence with the individual 

bay charging modules. The UCH0053 charger has six external charging ports whereas the UCH0054 

charger has two external charging ports.  Alternate approved batteries that are unable to be inserted into 

the internal bays for charging (UBBL35, UBBL06, UBBL08, etc.) can be connected to the external charging 

ports using Ultralife approved charging cables. 
 

2.6 

Battery Adapters 

Ultralife supplies various battery adapters that allow charging of alternate approved batteries (UBBL06, 

UBBL08, etc).  The adapters mate to the 2590 charge port and are held in place using the supplied 

retention strap.  

 

2.7 

USB Technician Port 

The UCH0053/UCH0054 charger has USB type-B technician ports for the purposes of firmware upgrades. 

The UCH0053 charger has three USB type-B technician port whereas the UCH0054 charger has a single 

USB type-B technician port. In the event a firmware upgrade is required, such upgrade must only be 

completed by a qualified repair technician. 

 

2.8 

Wide Range Input Voltage 

The UCH0053/UCH0054 chargers allow for AC and DC input power to be connected simultaneously. The 

charger will automatically detect the presence of either AC or DC, and will switch power preference to AC 

when available. The transition from a DC power source to an AC power source is seamless to the user. When 

removing AC power with DC power present, the UCH0053/UCH0054 charger may go through a power cycle 

to prevent damage to the unit. 

 

 

 

Содержание UCH0053

Страница 1: ...NY 14513 USA Telephone 315 332 7100 FAX 315 331 7800 E MAIL sales ulbi com Website www ultralifecorporation com Copyright 2017 Ultralife Corporation All Rights Reserved Disclaimer of Liability Inform...

Страница 2: ...of Liability 1 1 ABOUT THIS MANUAL 1 1 Symbols Used 5 1 2 General Safety Instructions 6 2 PRODUCTDESCRIPTION 2 1 Charge Safety 7 2 2 xx90 Battery Detection 7 2 3 Charger Operational Temperature 8 2 4...

Страница 3: ...1 AC Input Circuit Breaker 10 13 Internal Battery Bay 4 HH Interface 10 2 DC Input Circuit Breaker 10 14 Internal Battery Bay 5 HH Interface 10 3 AC Inlet 10 15 Internal Battery Bay 6 HH Interface 10...

Страница 4: ...re unavailable for use on some selected versions of the UCH0053 UCH0054 chargers 14 3 5 Charging via Adapters 14 3 6 USB Charging Port 15 3 7 AC DC Circuit Breakers 15 3 8 Battery Calibration 15 3 9 S...

Страница 5: ...ese safety WARNINGS and CAUTIONS must be followed at all times WARNING Warning statements mean danger They identify practices procedures or conditions such as high voltage that could result in injury...

Страница 6: ...e unit to wet conditions rain or snow with the lid open Use of an attachment not recommended or sold by Ultralife Corporation may result in risk of fire damage to the charger electric shock or persona...

Страница 7: ...d caution instructions located in section 1 to prevent the mischarge or catastrophic destruction of a battery While inherently safe misuse of the UCH0053 UCH0054 charger may result in damage to the ba...

Страница 8: ...individual bay charging modules The UCH0053 charger has six external charging ports whereas the UCH0054 charger has two external charging ports Alternate approved batteries that are unable to be inser...

Страница 9: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 Figure 1 UCH0054 Charger Top View 1 AC Input Circuit Breaker 9 Adapter Cable Storage Pocket 2 AC Inlet 10 Fan Outlet 3 DC Input Circuit Breaker 11 Internal Battery B...

Страница 10: ...ttery Bay 5 HH Interface 3 AC Inlet 15 Internal Battery Bay 6 HH Interface 4 DC Input Banana Jacks 16 Internal Battery Bay 1 xx90 Interface 5 Technician Ports 17 Internal Battery Bay 2 xx90 Interface...

Страница 11: ...ately sized WARNING Never alter the AC cord or plug provided Improper connection can result in a risk of an electrical shock Ultralife Corporation recommends a minimum of 16 AWG wire be used for the A...

Страница 12: ...X batteries are inserted the UCH0054 charger is able to charge four batteries at one time whereas UCH0053 charger will charge twelve batteries at one time The battery type is automatically detected wh...

Страница 13: ...completely recharge the batteries listed in the chart below Battery Description Approximate Charge Time UBI 2590 Lithium Ion Li ION 12 24 VDC 3 to 5 hours BB 2590 U Lithium Ion Li ION 12 24 VDC 3 to 5...

Страница 14: ...arge is complete on a set of batteries the charger will automatically switch to the next set of batteries requesting charge It is not recommended to charge batteries that are not listed in the table a...

Страница 15: ...at the time of the switch activation If no batteries are requesting calibration pressing the calibration switch will force the calibration routine on all non smart batteries connected to the charger...

Страница 16: ...Greater than 65 C Battery is not properly inserted Charger is unable to charge the battery Internal charger temperature is too high 3 10 4 Calibration Request Indicator LEDs The amber LED labeled CAL...

Страница 17: ...and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 17 of 21 3 10 6 AC DC Supply Indicator LEDs The AC and DC supply LEDs indicate the active power source for the UCH0053 UC...

Страница 18: ...tion dampened non abrasive cloth With power removed rinse with a water dampened non abrasive cloth and allow to air dry or wipe dry with a clean dry non abrasive cloth Be sure all areas are dry before...

Страница 19: ...ompleted Steady Red Fault Failure Flashing Calibration LED Amber Calibration request Steady Calibration LED Amber Calibration started Table 3 Electrical Characteristics Parameter Value DCIN Operating...

Страница 20: ...d herein is for reference only and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 20 of 21 6 1 Contact Return Information Please call 315 332 7100 to obtain an RMA number pr...

Страница 21: ...com All specific subjects to change without notice The information contained herein is for reference only and does not constitute a warrant of performance 08 SEP 17 UBI 05346 REV Page 21 of 21 Revisi...

Отзывы: