Table 1: Physical Characteristics
Dimension
Measurement (UCH0054)
Measurement (UCH0053)
Width
327 mm (12.87 inches)
428 mm (16.85 inches)
Length
420 mm (16.54 inches)
609 mm (23.98 inches)
Depth
180 mm (7.09 inches)
263 mm (10.35 inches)
Weight (w/o Batteries)
5.9 kg (13 lbs.)
15.9 kg (35 lbs.)
Table 2: LED Indicators
Indicator
Meaning
Flashing Amber
Battery Detection
Steady Amber
Fast Charge
Steady Green
Fast Charge Completed
Steady Red
Fault / Failure
Flashing Calibration
LED (Amber)
Calibration request
Steady Calibration
LED (Amber)
Calibration started
Table 3: Electrical Characteristics
Parameter
Value
DCIN Operating Range
10-36 VDC. At 10-18V, the Battery Charge rate is half the normal rate
listed below.
ACIN Operating Range
100-240 VAC 50-60 Hz
Charge Rate
3A PER SIDE (UBI-2590, BB-2590/U, UBBL35, UBBL06, UBBL08)
2A PER SIDE (PRC-148, PRC-152)
480mA PER SIDE (BB-390/U, BB-590/U)
Note: Charge rates are reduced for input voltages less than 18VDC.
NOTE: The Power Input requires a maximum of approximately 250 watts for the UCH0054, and 750
watts for the UCH0053. Input current will vary depending on the voltage. Ultralife Corporation
recommends a minimum of 12 AWG wire be used for the DC power cable for the UCH0054, and 10
AWG for the UCH0053. Ultralife Corporation recommends a minimum of 16 AWG wire be used for
the AC power cable.