2-8
2.5.1
120 Vac or 220 Vac Input Power.
The input power for the control receiver is configured at the factory. There
is no setup on the mother board for input power. However, Model CRX-502
and CRX-520 Receivers have an expansion board that has jumpers that
must be in the correct positions for 120 Vac or 220 Vac input power.
WARNING
ENSURE POWER IS DISCONNECTED FROM
THE CONTROL RECEIVER. PERSONNEL
INJURY COULD RESULT FROM
ELECTRICAL SHOCK.
Model CRX-502
Expansion Board
and CRX-520
Jumpers
Power
W1
W2
W3
120 Vac
In
In
Out
220 Vac
Out
Out
In
Содержание CRX-501