PRE-INSTALLATION: 

Safe and satisfactory operation of a Model ZRT3-H gas fryer depends on its proper installation.  Installation must conform 

        to local codes or, in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1 (latest edition).  In Canada, gas installa-

        tion shall be in accordance with the current CAN/CGA B 149.1 and .2 installation codes and/or local codes.

                  

GENERAL: 

Each Model ZRT3-H fryer should be installed as follows:

        A.    Placed beneath a properly designed exhaust hood

        B.    Installed by a licensed plumber.

        C.    Connected to the type gas for which the unit was fabricated as shown on the rating plate.

        D.    Connected to the proper size pressure regulator installed in the gas supply line and adjusted to the proper manifold pressure.

        E.     Connected to the main gas supply line with the proper size supply line.

        F.     Restrained by use of a restraining device to avoid splashing of hot liquid and to assure tension cannot be placed on the flexible gas line or 

fittings.

CLEARANCES

:  The appliance must be kept free and clear of all combustibles.  The minimum clearance from combustible and 

non-combustible construction is 6” (152 mm) from the sides, and 6” (152 mm) from rear.  The fryer may be installed on combustible floors.

        

NOTE

:  Adequate clearances must be provided for servicing and proper operation.

STANDARDS: 

  Installation must be planned in accordance with all applicable state and local codes, taking into account the following standards:

        A.    The fryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that 

system at pressures in excess of 1⁄2 psig (3.45kPa).  In Canada, gas installation shall be in accordance with the current CAN/CGA B 149.1 

and .2 installation codes and/or local codes.

         B.     The fryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply 

piping system at pressures equal to or less than 1⁄2 psig (3.45kPA).

         C.     When installed the fryer must be electrically grounded in accordance with local codes, or in the absence of local codes, in accordance with the current 

National Electrical code ANSI/NFPA 70 (latest edition).  In Canada electrical installation must be in accordance with the current CSA C22.1 Canadian Elec-

trical Code and/or local codes.

         

D.    Other applicable nationally recognized installation standards such as:

                1.     National Fuel Gas Code ANSI Z223.1 (latest edition)

                        American Gas Association

                        1515 Wilson Blvd.

                        Arlington, VA22209

                2.     NFPA Standards #54, #94 and #221 (latest edition)

                        National Fire Protection Association

                        470 Atlantic Avenue

                        Boston, MA 02110

                3.     ANSI Z21.69/CAN/CGA-6.16 AND Z21.41/CAN1 6.9

        E.     Exhaust hood, when installed must conform to the current NFPA 54-1 and Canadian CAN/CGA-1.11 (latest edition)

                 

NOTE:

  Local building codes will usually not permit a fryer with its open tank of hot oil to be installed immediately next to an open flame 

                      of any type, whether a broiler or an open burner or range.  Check local codes before beginning installation.

AIR SUPPLY AND VENTILATION:  

The area around the appliance must be kept clear of any combustible or flamable products and  avoid any 

obstruction to the flow of ventilation air as well as for ease of maintenance and service.  

NOTHING 

is to be stored in the interior of the 

fryer’s cabinet except the filter tub assembly.

        A.    A means must be provided for any commercial, heavy duty-cooking appliance to exhaust combustion wastes outside of the building. It is 

essential that a fryer be set under a powered exhaust hood or that an exhaust fan be provided in the wall above the unit, as exhaust tempera-

tures are in the vicinity of 400°F (204ºC).

        NOTE: 

  Strong exhaust fans in a hood or in the overall air conditioning system can produce slight air drafts in the room, which can interfere 

                with burner performance and be hard to diagnose.  Air movement should be checked during installation and if burner problems persist, 

make-up air openings or baffles may have to be provided in the room

.

        B.    Exhaust temperature, in addition to the open tank of hot oil, make the storage of anything on shelving over or behind the fryer unsafe.

        C.    Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and installing any hood.

        D.    Provisions must be made for an adequate supply of fresh air and adequate clearance must be maintained for air openings into the combus-

tion chamber.

RECEIVING & INSTALLING THE FRYER

         A.   UNPACKING:  

Check that the container is upright.  Use an outward prying motion – 

DO NOT USE A HAMMER 

-  to remove the 

carton.  Check the fryer(s) for visible damage; if such damage has occurred do not refuse shipment, but contact the carrier and file the 

appropriate freight claims.

        B.    INSTALLING:  

Roll the assembled fryer bank into the building, proceed to next paragraph.

                        

        

WARNING:   IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE 

                PROPERTY DAMAGE, INJURY OR DEATH.  READ THE INSTALLATION, OPERATING AND MAINTENANCE 

                INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.

 

LEVELING:

        A.    When the fryer is placed in its operating location check to be sure it is level.  If not, loosen the casters and insert the appropriate number 

                of shim plates between leg and caster plates then retighten the caster bolts.  

        B.    If the floor is smooth and level, adjust to the high corner and measure with a spirit level.  If the floor is uneven or has a decided slope, 

                level the unit with metal shims.

        NOTE:  

A caster may not return exactly to the same position after being moved, which may require re-leveling after each move.

7

Содержание ZRT3-H

Страница 1: ...r Lane P O Box 5369 San Antonio Texas 78201 800 525 8130 210 731 5000 Fax 210 731 5099 WARNING TO PRECLUDE THE POSSIBILITY OF SPONTANEOUS COMBUSTIBLE FILTER TUB FIRES SLUDGE AND CRUMBS MUST BE REMOVED...

Страница 2: ...nt Ultrafryer Systems for use by personnel who will operate a 14 or 18 Model ZRT3 H Gas Fryer equipped with an EZ Dock Filtration System TECHNICAL PUBLICATIONS DEPARTMENT ULTRAFRYER SYSTEMS 302 SPENCE...

Страница 3: ...on Electrical Connections Default To Manual Restart DTMR Control Optional Controls INITIAL START UP Cleaning Start up Lighting Instructions Sequence Of Ignition Burner Operation Test Shortening Instal...

Страница 4: ...1 Cooking Computer Filtering Shortening Filter Tub Assembly Installation Filtering Polishing Shortening Fryer Boil Out Shortening Disposal Shortening Installation TECHNICAL ASSISTANCE ORDERING INFORMA...

Страница 5: ...GENERAL INFORMATION 1...

Страница 6: ...fy an authorized service agent to make repairs during normal hours or after hours Any parts that need to be shipped back to Ultrafryer Systems will be shipped back prepaid by the customer marked with...

Страница 7: ...rs may request the fryer be equipped with an Ultrastat 21 or Ultrastat 25 Cooking Computer In addition the 14 18 Model ZRT3 H are equipped with the NEWLY developed EZ Dock Filtration System that uses...

Страница 8: ...14 MODEL ZRT3 H GAS FRYER 18 MODEL ZRT3 H GAS FRYER 14 18 MODEL ZRT3 H GAS FRYER CONTROL LOCATIONS 4...

Страница 9: ...previous page AUTOMATIC SAFETY FEATURES A High limit thermostat to shut off gas to the main burners by opening a solenoid actuated safety valve in the combination gas control valve B Combination gas...

Страница 10: ...ryer and main gas regulator locate the FT3 HR M3 HR of gas required for the fryer and pipe length and read the pipe diameter on the top row For example a 14 ZRT3 H fryer operating on NATURAL GAS requi...

Страница 11: ...when installed must conform to the current NFPA 54 1 and Canadian CAN CGA 1 11 latest edition NOTE Local building codes will usually not permit a fryer with its open tank of hot oil to be installed i...

Страница 12: ...R S COMBINATION GAS CONTROL VALVE EXCEEDS 1 2 lb in2 035 kg cm2 OR APPROXIMATELY 14 356 mm W C AN EXTERNAL REGULATOR MAY BE NEEDED TO PREVENT DAMAGE TO THE COMBINATION GAS VALVE AND VOIDING OF WARRANT...

Страница 13: ...START BUTTON When this button is momentarily depressed it places the fryer in operation RED STARTED LAMP When lit indicated the START BUTTON has been momentarily depressed and the fryer is operating A...

Страница 14: ...valve behind the fryer control access door of the fryer to the OFF position and wait FIVE 5 minutes for any accumulated gas to disperse 4 ENSURE the MAIN gas shut off is in the ON position MANUAL VAL...

Страница 15: ...pre set shortening cook temperature within 2 of the pre set temperature B START UP 1 TO TEST OPERATE an Ultrafryer Gas Fryer equipped with a Default to Manual Restart DTMR control a Ensure the fryer...

Страница 16: ...IT MELT key HEAt will appear in the computer display to indicate it is in the FULL ON mode 3 Depress the TEMP key ONCE The ACTUAL water temperature will be shown in the computer display NOTE DEPRESS T...

Страница 17: ...If shortening is needed use the filter scraper to cut off a small block of solid shortening 3 Place the small block of shortening into a fry basket lower the basket into the shortening then turn the...

Страница 18: ...ng handle skimmer to pull congealed shortening UPWARD from the Cold Zone area 6 When shortening has reached the set temperature and the RED indicator lamp on the fryer has turned OFF allow the Electro...

Страница 19: ...y have over heated and shut off on thermal over load If this situation did occur it will correct itself when the mo tor cools 10 20 minutes If this overheating problem persists re place the blower mot...

Страница 20: ...rtment at 1 800 525 8130 for technical assistance or to perform any maintenance or repair that may be necessary CLEANING Any item of equipment operates better and lasts longer when it is kept clean an...

Страница 21: ...t FINGER LOOP on FRAME B EVENLY pull the frames apart then HINGE FRAME A to remove it from the FILTER SCREENS FIRST c Grasp the FINGER LOOP on the straight side of FRAME B then HINGE it to remove FRAM...

Страница 22: ...re inserted in the other CHANNEL of FRAME B and the PIN on FRAME B is seated in the CHANNEL of FRAME A 9 Adjust FRAME A and B so other PINS are properly seated in the CHANNEL of the opposite frame the...

Страница 23: ...the OFF position and wait FIVE 5 minutes for any accumulated gas to disperse 3 ENSURE the MAIN gas shut off valve is in the ON posi tion and that the EXHAUST FAN is ON 4 Turn the MANUAL gas valve to t...

Страница 24: ...display ACTUAL TEMPERATURE when depressed ONCE Used to display SETPOINT TEMPERATURE when depressed TWICE Used to display remaining TIME when depressed THREE TIMES EXIT MELT 1 Used to manually exit the...

Страница 25: ...MP key THREE 3 times 4 Steps 1 2 3 and 4 will have to be repeated each time any of the following occurs DRAIN VALVE IS OPENED FRYER TOGGLE ON OFF SWITCH IS TURNED OFF TO FILTER SHORTENING OR BOILOUT A...

Страница 26: ...le sediment and debris on the heat exchanger and vat sides push in the Vat Shortening RETURN LEVER and procede to the following paragraph g below g An AUTOMATIC VAT CLEANER AVC Spray Blaster is an opt...

Страница 27: ...ENING INSTALLATION A GENERAL Shortening in the Model ZRT3 H Gas Fryer should be BOILED OUT every 7 DAYS to remove carbon buildup and other encrusted material B SHORTENING DISPOSAL 1 CAREFULLY assemble...

Страница 28: ...ilter tub C BOIL OUT Boil out the ZRT3 H Gas Fryer following the cleaning instructions in the Cleaning Manual provided by your approved chemical supplier The following are generic proceduress DTMR EQU...

Страница 29: ...E HANDLE to the closed UP position then fill the fryer with NEW shortening to the applicable shortening level mark as prescribed below 13 Reprogram the Ultrastat 11 Cooking Computer for the correct co...

Страница 30: ...nd will gladly assist you in preparing and processing of the necessary claims only if proper notification has been accomplished on the carrier delivery document Damaged equipment and or containers mus...

Страница 31: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 32: ...27 ULTRAFRYER MOCEL ZRT3 H GAS FRYER FRONT VIEW 14 ZRT3 H 18 ZRT3 H...

Страница 33: ...Drain Ball Valve Assembly 19A564 17 Ignitor Spark Rod Assembly w Ignitor Rod Set Rod Gap to VVE 4mm prior to installation 19A738 18 Sound Weldment Baffle 19A739 19 Docking Release Handle 19A948 20 14...

Страница 34: ...8 High 146 x 208mm Rectangular Flue Tube with deflector 18 Model ZRT3 H 73 4 x 111z High 197 x 281mm Rectangular Flue Tube with deflector 19A910 19b312 7 125 Volt 75 Watt Silicon Heater 5 1524mm Long...

Страница 35: ...R Lens 23A056 6 COOKING CONTROLS Default To Manual Restart DTMR Control f 14 18 Model ZRT3 H Uses Electronic Thermostat PN 12B077 Ultrastat 11 Cooking Computer Uses Temperature Probe 18A006 12B014 22A...

Страница 36: ...edium Duty Caster 28A005 ITEM DESCRIPTION PN 1 6 1829mm Wash Down Hose w Fittings 12 54 2 Wash Down Hose Nozzle Assembly 12 675 3 Proximity Sensor Switch 18A060 4 Cool II Handle 22 734 5 1 2 13mm S S...

Страница 37: ...I Handle 22 734 3 1 2 13mm HH 2236 SQ Spray Nozzle 22A111 4 1 2 13mm x 90 Black Iron Elbow 24 007 5 1 2 13mm 5 Way Black Iron Crossover Manifold 24A082 6 14 ZRT3 H 1 2 13mm x 51 4 133mm Black Iron Nip...

Страница 38: ...33 15 0 WIRING DIAGRAM Since minor wiring changes may occur in the future USE the diagram pasted to the fryer for circuit tracing and or troubleshooting a Model ZRT3 H Gas Fryer...

Отзывы: