36
Initial Start-up Step-By-Step Instructions
Rev D
Step 8: Estimated Capacity
•
System capacity is displayed in total kilograins or kilograms of
hardness removed before a regeneration is necessary.
•
Value is derived from the system’s resin volume input, and salt
amount input.
•
The capacity displayed is a suggested value – as recommended by
resin manufacturers.
•
Capacity is only displayed for information purposes on 742 control – it
cannot be changed.
•
To change capacity on 762 control, press SET to make the default
capacity flash. Use the UP and DOWN buttons to increment to the
desired capacity.
•
Press SET to accept the setting and advance to the next parameter.
•
FA filters
: see section on capacity,
Setting the 700 for 5-Cycle Filter
Applications
.
If using the 742 control, programming is complete. The control will return
you to the normal operation mode.
Step 9: Enter Hardness (762 Demand Control Only)
•
Enter inlet water hardness at installation site.
•
Default hardness setting is 25 grains (25 ppm for metric).
•
To change hardness, press SET to make the setting flags. Use the UP
and DOWN buttons to scroll to the correct hardness.
•
Press SET to accept the entered hardness value.
•
The control will return you to the normal operation mode.
•
FA filters
: see section on capacity,
Setting the 700 for 5-Cycle Filter
Applications
.
Initial system programming is now complete. The control will return to
normal operation mode, if a button is not pushed for 30 seconds.
Viewing Cycle Times
1. Press and hold the UP and SET buttons for 3 seconds when the control
is in the "in service mode" to access the "cycle time display mode". The
display will show a small "c" followed by a number in the lower portion
of the display.
2. Press the UP and DOWN buttons to display the programmed cycle
time.
3. Press the REGEN button to exit the "cycle times display mode".
Adjusting Cycle Times
1. Press SET when in the "cycle time display mode". The cycle time in
minutes will flash, indicating the cycle time can be changed.
2. Press the UP or DOWN buttons to change the flashing time.
3. Press SET while the cycle time is flashing to enter the flashing value.
KG
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness
KG
Time & Day
Regen Time & Day
Salt
SU MO TU
WE TH
FR
SA DAYS
Capacity
Hardness