20
Regenerant Line Connection
Rev D
Figure 11
Regenerant Connection for
Performa Valve
An aircheck must be used in the regenerant line when installing a
Performa valve.
NOTE:
When installing a 3-cycle filter (253, 263, or 273 valve) use a cap
on the regenerant line connection to prevent water seepage from the
port. See
Parts and Accessories
section for part number.
Regenerant Line Connection
NOTE:
Be sure to use a 3/8 inch NPT
plumbing connection when attaching
regenerant line to the Performa valve.