32
742/762 Series Initial Power-Up
Rev D
742/762 Series Initial Power-Up
Initial Power Up – (Camshaft proceeds to HOME position)
•
At initial power-up, the camshaft may need to rotate to the HOME (in
service position).
•
Camshaft may take 1 to 2 minutes to return to HOME position.
•
Err 3 will be displayed until the camshaft returns to HOME position.
•
If more than 2 minutes elapses, verify that the motor is turning the
camshaft. If it is not turning, contact Dealer.
Initial Start-up Step-By-Step Instructions
For FA filter applications, please program as normal below. See section
Programming the 700 for 5-Cycle Filter Applications
.
Step 1: Select Valve Type
This step may have been performed by your system’s OEM manufacturer.
In this case, proceed to step 3.
•
Identify your valve body type by looking at the silver ID sticker on the
back or side of the valve body.
•
Select your valve body type using the UP and DOWN buttons.
•
Display
Valve Body
255
255, 7-cycle conditioner
263
Performa filter 263, 3-cycle filter
268
Performa conditioner 268, 7-cycle conditioner
273
Performa Cv 273, 3-cycle filter
278
Performa Cv 278, 5-cycle conditioner
293
Magnum Cv filter, 3-cycle filter
298
Magnum Cv conditioner, 7-cycle conditioner
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH
FR
SA DAYS
NOTE:
The 700 Series controller features a self-test sequence. At first
power-up of the control, you may see a number such as 1.00, 1.02, 1.04,
or 2.00 displayed. This is an indication that the self-test is not
completed. To complete the test, verify that the turbine cable is
connected. Blow air into the turbine port (valve outlet) to spin the
turbine. The controller will verify that the turbine works and the self-test
will finish. Proceed with the initial start-up procedure.
NOTE:
Different 742/762 control hardware is necessary to operate the
150S valve body.