The UltimateAir® RecoupAerator® 200DX Manual and Installation Guide, March 2014
In some installations, the unit may be too noisy for the occupants. Here are
some options for correcting the situation:
1.
When installing the unit, allow for a three-foot section of insulated
flexible duct to go from the starting collar on the unit to the rest of the
ductwork (on all four collars). This will help dampen noise being
transmitted from the unit into the home or business, at the source.
2.
Locate the unit farther away from the source of the noise pollution area
(e.g., if the unit is close to a living room vent where the noise is too loud,
locate the unit farther away from this location). This will allow the noise
to dissipate in the longer duct length.
3.
Wire the RecoupAerator to run only with the furnace air handler.
4.
Run at the lowest flow setting necessary for fresh air requirements.