The battery becomes warm after cycles of charge/discharge process.The
program will insert a time delay after each charge/discharge process to
allow the battery enough time to cool down before beginning next cycle of
charge/discharge process.The valid value ranges from 1 to 60 minutes.
This function monitors the voltage of the input battery used to power this
charger.If the voltage is lower than user-set value,the program will end
forcibly to protect the input battery.
The beep to confirm users'operation sounds every time a button is pressed.
The beep or melody sounds at various times during operation to confirm
different mode change.These functions can be switched on or off.
The program provides maximu
m
capacity protection function.If the Delta-
peak voltage can not be detected or the safety timer times out,the charge
process will stop automatically,when the battery reaches the user-set
maximum charge capacity.
When the charge process starts,the integrated safety timer starts to run
simultaneously.If error detected or the termination circuit can not detect
whether the battery is fully charged or not,this unit is programmed to
prevent overcharging.Please refer to the below statement to calculate the
timer you set.