10. Setting the mode 

 

・Calling up and modifying the mode setting 

     When a mode is set, operate each key according to the following table. 
 

Operating key 

Display unit 

Operation procedure 

 
 

 MODE   +   >    

 
 A  B  C  D  E  F 
 0  1. 

  0  0  0 

   ↑ 

Mode No.

 

 
While holding down the  MODE  key, press the 

 >  key for 2 seconds or more. 

“0 1 ”  appears  in  displays  A-B  and  the  value 
setting 
for mode 01 is shown. 

 
 
        ∧  
 
 

 
 A  B  C  D  E  F 
 0  1. 1 

  0.0 

             ↑ 
           0 to 9 

 
Change the blinking numeral value.  Every press 
raises the value by ones. 
(0 → 1 → 2・・・9 → 0・・・) 

 
 
        ∨  
 
 

 
 A  B  C  D  E  F 
 0  1. 1 

  0.0 

             ↑ 
           0 to 9 

 
Change the blinking numeral value.  Every press 
reduce the value by ones. 
(0 → 9 → 8・・・1 → 0 →9・・・) 

 
 
        >  

 
 A  B  C  D  E  F 
 0  1. 1 

  0 .0

 

           →  →  → 
 

 
Change the blinking indication position (figure).
Every press moves the position to the right 
by a figure. 

 
 
       MODE  
 
 

 
 A  B  C  D  E  F 
 0  2. 

  0  1  1 

   ↑ 

01 to 16 

 
Change  the  mode  number.    Every  press  raises  the 
number by one.  There are 16 modes in total. 
When it reaches 16, it returns to 01. 
(01 → 02 → 03・・・16 → 01・・・) 

 
 
        ENT  
 
 

 

 
After adjusting the setting, make registration 
with this key. It returns to the measuring mode 
after registration. 

 
 
        RES  
 
 
 

 

 
Even by pressing this key during the time 
setting the mode, it returns to the measuring 
mode. Pay attention to the fact that the set 
data is not memorized. 

 
    Note  : In case you change mode setting, turn OFF mode protect. 
             If it is turned ON, change of mode setting will be made impossible. 
             (Refer to 27 page.) 

 
  ∨  Activated for 2 sec or more ・・・ 

               Mode protect ON  “L-ON” 

Mode protect OFF “L-OFF” 

Содержание SP-564A Series

Страница 1: ...ow less than 8mA Hi 16 20mA V3 Taco generator signal input AC 0 8V 80V P P 3KHz MAX N Sine wave signal input AC 0 05V 20V P P No entry Synchronous pulse output RS2 RS 232C communication RS4 RS 485 2 w...

Страница 2: ...and the like into the body Pay attention to an electric shock in wiring the power supply Do not touch a live terminal which is likely to cause an electric shock Do not disassemble the product nor tou...

Страница 3: ...zer upper display Upper digits 7 9 display by pressing Up key Reset Internal counter is reset using Reset key or input from terminal board 50 ms or more to activate in rear Input from terminal board N...

Страница 4: ...Rating DC 30 V 1 A AC 125 V 0 3 A Output indication During alarm output the OUT1 and OUT2 LEDs are activated Output reset Alarm reset using Reset key or input from terminal board 50 ms or more to act...

Страница 5: ...9 Communication system Communication is controlled by command RS 485 communication RS4 type RS4W type Signal standards 2 wire half duplex transmission RS4 type 4 wire half duplex transmission RS4W typ...

Страница 6: ...ar side terminal stand side as for the fitting for fixing the body It turns a screw by the driver The meter is fixed right and left both sides Fig 3 1 Please install it horizontally 2 Fit the body on...

Страница 7: ...when rate reading is indicated Totalizer lamp TO The totalizer lamp is activated when total reading is indicated EXT input lamp HD The EXT input lamp is activated when terminal No 4 and No 6 is short...

Страница 8: ...res Each time the key is pressed the number goes up by one Down key 1 Activated for 2 sec or more Mode protect ON Mode protect OFF 2 Changes the value of the blinking digit during setup procedures Eac...

Страница 9: ...ention to this matter If this is not right a protective part and the like may be damaged For DC power supply input If and are connected reversely the internal protective circuit will function to stop...

Страница 10: ...Proximity sensor Encoder C Ground contact output sensor D Tacho generator signal Fig Sine wave signal output sensor Fig 1 Current pulse input Current pulse input 2 wire pulse sensor Fig 1 3 wire pulse...

Страница 11: ...Pulse sensor input NPN open collector pulse input Fig 13 Voltage pulse input Fig 14 2 Tacho generator signal input Sine wave signal input Fig 15 3 Reset input Fig 16 Sensor power DC12V standard R1 2 2...

Страница 12: ...ted by setting the dip switch Table 1 SW1 1 SW1 2 SW1 3 SW1 4 OFF ON open collector pulse ON Voltage pulse OFF Input frequency Low OFF ON Input frequency Mid ON OFF Input frequency Hi OFF OFF 1 2 3 4...

Страница 13: ...12 8 Test mode...

Страница 14: ...ting Totalizer Table 3 Initial setting Notes Offset Indication Initialization Power on Enter key being pressed to initialize the settings After the initialization the set values will be as shown in Ta...

Страница 15: ...blinking indication position figure Every press moves the position to the right by a figure MODE 01 to 16 Change the mode number Every press raises the number by one There are 16 modes in total When i...

Страница 16: ...acts as magnification EXP value With input of this converter and EXP value it is possible to set the magnification per 1 pulse This EXP value is set with Mode 02 For instance with display of instant f...

Страница 17: ...nly 0 or 5 display EXP value 0 9 This mode 02 C is EXP value input as explained in mode 01 Mode No Display sampling time Sampling time 00 1 99 9 seconds 00 0 corresponds to 100 sec For display samplin...

Страница 18: ...is not correct Input pulse First time Moving average Second time Calculating display Third time Note In relation to the calculation use the input pulse in case of less than 20Hz In case of higher freq...

Страница 19: ...ator is possible by the terminal input Accepts no sensor inputs Holds the current indication while blinking Internally count calculations are continued Indicator A change of the indicator is possible...

Страница 20: ...alue 0 9 Reset time The setting for the front panel Reset key is specified The Reset key is pressed for 2 seconds or longer for the count to be reset The count is reset immediately when the Reset key...

Страница 21: ...r rate synchronized rate display 1 for rate real time 2 for total count Selecting between rate total The value to be outputted is selected It outputs synchronizing with the sampling time Real time out...

Страница 22: ...follows Mode 09 Output synchronized with totalizer Right 4 digits Mode 10 Maximum output indication is 5000 Mode No Output digit and output width for synchronized pulse Set up output width 0 01 1 99s...

Страница 23: ...eter Compare rate meter indication value to Preset value Totalizer Compare totalizer indication value to Preset value OUT1 Alarm output adapt itself to Mode No 13 and please set it OUT2 alarm output s...

Страница 24: ...arm disable time interval Startup by setting 00 Upper and lower limits selection Select that this is output when the upper limit is exceeded or when the lower limit is exceeded Output mode The length...

Страница 25: ...able time interval 00 99 sec Each setting is the same as that of the Mode 13 Alarm output OUT1 Output mode 8 and 9 Zero return When an indication value exceeds the specified value preset value this ou...

Страница 26: ...ed Communication Communication selection Set the zero in the case of unit except communication option Mode No Setting the communication RS2 type RS4 type RS4W type Interval time 100 ms 50 ms 10 ms 60...

Страница 27: ...rflow OV lamp is blinking activated when the total exceeds 999999 or 99999 While blinking indication it continues measurement from 000000 or 00000 3 The over times the overflowed upper 3 digits are di...

Страница 28: ...ime of the shipment becomes OFF Operation of the mode protect 1 If setting it finish setting 2 Activated for 2 sec or more 3 Current mode protect state is displayed when it passes for 2 sec Mode prote...

Страница 29: ...tting value is shown in displays Change the blinking indication position figure Every press moves the position to the right by a figure 0 to 9 0 to 9 Change the blinking numeral value A number goes up...

Страница 30: ...e together with Shift key Display A Setting MODE The OUT2 lamp lights up and the preset value setting for OUT2 is shown Each time the key is pressed OUT1 and OUT2 switch OUT1 OUT2 OUT1 ENT After adjus...

Страница 31: ...d correctly at the factory Please do not touch except necessity V3 type Taco generator signal input AC 0 8V 80V P P N type Sine wave signal input AC 0 05 20V P P While looking at display adjust an adj...

Страница 32: ...e 0 1 V Turn the zero volume to adjust 10 5 V Turn the span volume to adjust Repeat the procedure several times for fine adjustment For the voltage output AV4 type unit Indication Output voltage 0 0 V...

Страница 33: ...e meter data read 2 Totalizer data read fixed 3 Preset value OUT1 read fixed 4 Preset value OUT2 read fixed 5 Preset value OUT1 write fixed fixed 6 Preset value OUT2 write fixed 7 Reset 8 Indication i...

Страница 34: ...ition of the unit and a communication error are shown Status is shown in expressing HEX value in 2 byte character strings bit 7 OUT1 output condition 1 output bit 6 OUT2 output condition 1 output bit...

Страница 35: ...34 Internal circuit 1 RS 232C RS2 type Fig 22 2 RS 485 2 wire RS4 type Fig 23 N C 3 RS 485 4 wire RS4W type Fig 24...

Страница 36: ...35 18 External dimensions Fig 2 Fig 26 48 0 5 0 45 70 or more...

Страница 37: ...ike may be revised for improvement without prior notice which please understand and accept Head Office 123 1 Kami Nishiku Sakai city Osaka Japan TEL 81 72 274 6001 FAX 81 72 274 6005 Tokyo Branch TEL...

Отзывы: