![UINICS SP-564A Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/uinics/sp-564a-series/sp-564a-series_instruction-manual_3284762026.webp)
- 25 -
Mode No.
Setting the communication RS2-type / RS4-type / RS4W-type
A B C D E F
1 5.0 1 0 3
Baud rate
0:1200 bps
1:2400 bps
2:4800 bps
3:9600 bps
Parity bit
0:None
1:Even
2:Odd
Data bit
0:7 bit
1:8 bit
Communication selection
0:Not used(※)
1:Communication
15
Communication selection:Set the zero in the case of unit except communication
option.
Mode No.
Setting the communication RS2-type / RS4-type / RS4W-type
A B C D E F
1 6.0 0 0
Interval time
0:100 ms. 5:50 ms.
1:10 ms. 6:60 ms.
2:20 ms. 7:70 ms.
3:30 ms. 8:80 ms.
4:40 ms. 9:90 ms.
Selection of the unit(ID number):00-99
16
Interval time:Wait time when switching to receive signal from send signal,
or to send signal from receive signal.